QMH26 Series, Photoelectric, Industrial

Results:
10
Manufacturer
Series
Sensing Distance
Light Source
Adjustment Type
Output Configuration
Sensing Method
Connection Method
Cable Length
Operating Temperature
Ingress Protection
Response Time
Voltage - Supply
Results remaining10
Applied Filters:
QMH26
Select
ImageProduct DetailPriceAvailabilityECAD ModelCable LengthOperating TemperatureVoltage - SupplySensing MethodAdjustment TypeResponse TimeSensing DistanceOutput ConfigurationLight SourceConnection MethodIngress ProtectionSeries
QMH26VNLPQ7
QMH26 HYGIENIC SERIES: STANDARD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-30°C ~ 70°C
10V ~ 30V
Retroreflective
-
500µs
118.110" (3m)
NPN - Dark-ON/Light-ON
Red (620nm)
Connector, M8
IP69
QMH26
QMH26VNAF400Q7
QMH26 HYGIENIC SERIES: ADJUSTABL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-30°C ~ 70°C
10V ~ 30V
Background Suppression
Adjustable
500µs
15.748" (400mm)
NPN - Dark-ON/Light-ON
Red (620nm)
Connector, M8
IP69
QMH26
QMH26VNLP-5M
QMH26 HYGIENIC SERIES: STANDARD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Retroreflective
Teaching Method
500µs
118.110" (3m)
NPN - Dark-ON/Light-ON
Red (620nm)
Cable
IP69
QMH26
QMH26VNAF200Q7
QMH26 HYGIENIC SERIES: ADJUSTABL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-30°C ~ 70°C
10V ~ 30V
Background Suppression
Adjustable
500µs
7.874" (200mm)
NPN - Dark-ON/Light-ON
Red (660nm)
Connector, M8
IP69
QMH26
QMH26VNAF400-5M
QMH26 HYGIENIC SERIES: ADJUSTABL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Background Suppression
Adjustable
500µs
15.748" (400mm)
NPN - Dark-ON/Light-ON
Red (620nm)
Cable
IP69
QMH26
QMH26ENXLPCQ7
QMH26 HYGIENIC SERIES: LOW CONTR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-30°C ~ 70°C
10V ~ 30V
Retroreflective
Teaching Method
500µs
102.362" (2.6m)
NPN - Dark-ON/Light-ON
Red LED
Connector, M8
IP69
QMH26
QMH26VPAF200-5M
QMH26 HYGIENIC SERIES: ADJUSTABL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Background Suppression
Adjustable
500µs
7.874" (200mm)
PNP - Dark-ON/Light-ON
Red (660nm)
Cable
IP69
QMH26
QMH26VNAF200-5M
QMH26 HYGIENIC SERIES: ADJUSTABL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Background Suppression
Adjustable
500µs
7.874" (200mm)
NPN - Dark-ON/Light-ON
Red (660nm)
Cable
IP69
QMH26
QMH26EPXLPC-5M
QMH26 HYGIENIC SERIES: LOW CONTR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Retroreflective
Teaching Method
500µs
102.362" (2.6m)
PNP - Dark-ON/Light-ON
Red LED
Cable
IP69
QMH26
QMH26ENXLPC-5M
QMH26 HYGIENIC SERIES: LOW CONTR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
196.85" (5m)
-30°C ~ 70°C
10V ~ 30V
Retroreflective
Teaching Method
500µs
102.362" (2.6m)
NPN - Dark-ON/Light-ON
Red (620nm)
Cable
IP69
QMH26

Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.