GR18S Series, Photoelectric, Industrial

Results:
140
Manufacturer
Series
Sensing Distance
Response Time
Output Configuration
Operating Temperature
Sensing Method
Light Source
Ingress Protection
Connection Method
Cable Length
Adjustment Type
Voltage - Supply
Results remaining140
Applied Filters:
GR18S
Select
ImageProduct DetailPriceAvailabilityECAD ModelCable LengthVoltage - SupplyIngress ProtectionSensing MethodOutput ConfigurationOperating TemperatureAdjustment TypeResponse TimeLight SourceConnection MethodSeriesSensing Distance
GRL18S-F235Y
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRL18S-P235Y
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRTE18S-P2362
SENSOR PROXIMITY 1M PNP LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Proximity
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
1ms
Red (650nm)
Connector, M12
GR18S
0.197" ~ 39.370" (5mm ~ 1m)
GRL18S-E1331
SENSOR RETROREFLECTIVE 7.2M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
78.74" (2m)
10V ~ 30V
IP67
Retroreflective
NPN
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Cable
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRTE18S-P246Z
SENSOR PROXIMITY 1M PNP LO/DO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Proximity
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
1ms
Red (650nm)
Connector, M12
GR18S
0.197" ~ 39.370" (5mm ~ 1m)
GRL18SG-F233X
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
500µs
Red (650nm)
Connector, M12
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRL18S-F2356
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRL18SG-P1157
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
78.74" (2m)
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
500µs
Red (650nm)
Cable
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRTE18S-F234X
SENSOR PROXIMITY 550MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Proximity
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
1ms
Red (650nm)
Connector, M12
GR18S
0.197" ~ 21.654" (5mm ~ 550mm)
GRTE18S-P2447
SENSOR PROXIMITY 550MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Proximity
PNP
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
1ms
Red (650nm)
Connector, M12
GR18S
0.197" ~ 21.654" (5mm ~ 550mm)
GRL18S-N1351
SENSOR RETROREFLECTIVE 7.2M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
78.74" (2m)
10V ~ 30V
IP67
Retroreflective
NPN
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Cable
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRSE18S-P2336
SENSOR THROUGH-BEAM 100MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Through-Beam
PNP - Dark-ON/Light-ON
-25°C ~ 50°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
0.039" ~ 3.937" (1mm ~ 100mm)
GRSE18S-F2336
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
590.551" (15m)
GRSE18S-F1336
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
78.74" (2m)
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Cable
GR18S
590.551" (15m)
GRSE18S-F2338
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
590.551" (15m)
GRTE18S-N231Z
SENSOR PROXIMITY 115MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Proximity
NPN
-25°C ~ 55°C (TA)
Adjustable, Potentiometer
1ms
Red (650nm)
Connector, M12
GR18S
0.118" ~ 4.528" (3mm ~ 115mm)
GRL18S-P2431
SENSOR RETROREFLECTIVE 7.2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Retroreflective
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
1.181" ~ 283.465" (30mm ~ 7.2m)
GRSE18S-P133Y
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
78.74" (2m)
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Cable
GR18S
590.551" (15m)
GRSE18S-P233Y
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
590.551" (15m)
GRSE18S-F233W
SENSOR THROUGH-BEAM 15M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10V ~ 30V
IP67
Through-Beam
PNP
-25°C ~ 55°C (TA)
-
500µs
Red (650nm)
Connector, M12
GR18S
590.551" (15m)

About  Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.