SA1U Series, Photoelectric, Industrial

Results:
16
Manufacturer
Series
Sensing Distance
Output Configuration
Sensing Method
Voltage - Supply
Response Time
Light Source
Adjustment Type
Operating Temperature
Ingress Protection
Connection Method
Cable Length
Results remaining16
Applied Filters:
SA1U
Select
ImageProduct DetailPriceAvailabilityECAD ModelCable LengthOperating TemperatureIngress ProtectionOutput ConfigurationSeriesSensing MethodSensing DistanceVoltage - SupplyResponse TimeLight SourceConnection MethodAdjustment Type
SA1U-P07MT
SENSOR RETRO POL 7M SPDT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Retroreflective, Polarized
275.591" (7m)
12 V ~ 240 VDC, 24 V ~ 240 VAC
20ms
Red (660nm)
Terminal Block
Adjustable
SA1U-T50M
SENSOR THROUGH-BEAM 50M SPDT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Through-Beam
1967.5" (50m) 164.05'
12 V ~ 240 VDC, 24 V ~ 240 VAC
20ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-D01M
SENSOR REFLECTIVE 1M SPDT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Reflective, Diffuse
39.37" (1m)
12 V ~ 240 VDC, 24 V ~ 240 VAC
20ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-D01MT
SENSOR REFLECTIVE 1M SPDT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Reflective, Diffuse
39.37" (1m)
12 V ~ 240 VDC, 24 V ~ 240 VAC
20ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-P07M
SENSOR RETRO POL 7M SPDT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Retroreflective, Polarized
275.591" (7m)
12 V ~ 240 VDC, 24 V ~ 240 VAC
20ms
Red (660nm)
Terminal Block
Adjustable
SA1U-D01MW
PHOTOELECTRIC SENSOR DIFFUSE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Reflective, Diffuse
3.28' (1m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-D01MWT
PHOTOELECTRIC SENSOR DIFFUSE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Reflective, Diffuse
3.28' (1m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-P07MW
PHOTOELECTRIC SENSOR POLARIZE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Retroreflective, Polarized
22.97' (7m)
12V ~ 24V
1ms
Red (660nm)
Terminal Block
Adjustable
SA1U-P07MWT
PHOTOELECTRIC SENSOR POLARIZE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Retroreflective, Polarized
22.97' (7m)
12V ~ 24V
1ms
Red (660nm)
Terminal Block
Adjustable
SA1U-T50MW
PHOTOELECTRIC SENSOR THRU-BEAM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Through-Beam
164.04' (50m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-B02MW
PHOTOELECTRIC SENSOR BG SUPP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector, Light-ON\Dark-ON
SA1U
Background Suppression
78.740" (2m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
-
SA1U-T50MWT
PHOTOELECTRIC SENSOR THRU-BEAM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector
SA1U
Through-Beam
164.04' (50m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-B02MWT
PHOTOELECTRIC SENSOR BG SUPP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
NPN/PNP - Open Collector, Light-ON\Dark-ON
SA1U
Background Suppression
78.740" (2m)
12V ~ 24V
1ms
Infrared (870nm)
Terminal Block
-
SA1U-B02M
PHOTOELECTRIC SENSOR BG SUPP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT - Dark-ON/Light-ON
SA1U
Background Suppression
78.740" (2m)
24 ~ 240VAC, 12 ~ 240VDC
20ms
Infrared (870nm)
Terminal Block
-
SA1U-T50MT
PHOTOELECTRIC SENSOR THRU-BEAM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT
SA1U
Through-Beam
164.04' (50m)
24 ~ 240VAC, 12 ~ 240VDC
20ms
Infrared (870nm)
Terminal Block
Adjustable
SA1U-B02MT
PHOTOELECTRIC SENSOR BG SUPP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 60°C
IP67
SPDT - Dark-ON/Light-ON
SA1U
Background Suppression
78.740" (2m)
24 ~ 240VAC, 12 ~ 240VDC
20ms
Infrared (870nm)
Terminal Block
-

Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.