E3S Series, Photoelectric, Industrial

Results:
74
Manufacturer
Series
Sensing Distance
Ingress Protection
Sensing Method
Response Time
Light Source
Output Configuration
Connection Method
Voltage - Supply
Adjustment Type
Operating Temperature
Cable Length
Results remaining74
Applied Filters:
E3S
Select
ImageProduct DetailPriceAvailabilityECAD ModelCable LengthOperating TemperatureVoltage - SupplyOutput ConfigurationResponse TimeAdjustment TypeSensing DistanceSensing MethodSeriesLight SourceConnection MethodIngress Protection
E3S-5B41
SENSOR THROUGH-BEAM 5M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
PNP - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5DB41 2M
SENSOR THROUGH-BEAM 5M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
PNP - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5DB4 2M
SENSOR THROUGH-BEAM 5M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
PNP - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5DE41
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5DE4 5M
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5DE4S-45
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5E4
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5E41
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-5E41-40 5M
SENSOR THROUGH-BEAM 5M NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
3ms
-
196.850" (5m)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 3, 4X, 6, 12; IEC 144 IP67
E3S-GS3E4
SENSOR THRU-BEAM 30MM NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
1ms
Adjustable
1.181" (30mm)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 4, 4X, 12, 13; IEC 144 IP67
E3S-GS3E4 5M
SENSOR THRU-BEAM 30MM NPN DO/LO
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
NPN - Dark-ON/Light-ON - Selectable
1ms
Adjustable
1.181" (30mm)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 4, 4X, 12, 13; IEC 144 IP67
E3S-CT61-L-5 5M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
-
-
-
-
E3S
-
-
-
E3S-GS3B4
SENSOR THROUGH-BEAM 10MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
12V ~ 24V
PNP - Dark-ON/Light-ON - Selectable
1ms
Adjustable
0.394" (10mm)
Through-Beam
E3S
Infrared
Cable
NEMA 1, 4, 4X, 12, 13; IEC 144 IP67
E3S-AR81
SENSOR RETROREFLECTIVE 2M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 55°C
10V ~ 30V
PNP - Dark-ON/Light-ON - Selectable
500µs
Two-Turn Endless Adjuster with an Indicator
78.740" (2m)
Retroreflective
E3S
Red (700nm)
Cable
NEMA 4X; IEC IP67

About  Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.