BR Series, Photoelectric, Industrial

Results:
23
Manufacturer
Series
Sensing Distance
Output Configuration
Sensing Method
Light Source
Cable Length
Ingress Protection
Connection Method
Adjustment Type
Operating Temperature
Response Time
Voltage - Supply
Results remaining23
Applied Filters:
BR
Select
ImageProduct DetailPriceAvailabilityECAD ModelOperating TemperatureVoltage - SupplySensing MethodResponse TimeSeriesSensing DistanceConnection MethodIngress ProtectionCable LengthAdjustment Type
BRP100-DDT
SENSOR REFLECTIVE 100MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective, Diffuse
1ms
BR
3.937" (100mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR200-DDTN-C-P
SENSOR, PHOTO, DIFFUSE REFLECTIV
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Connector
IP66
-
Adjustable
BR20M-TDTL-C
SENSOR THROUGH-BEAM 20M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
787.402" (20m)
Connector
IEC IP66
-
Fixed
BR4M-TDTD-P
SENSOR THROUGH-BEAM 4M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
157.480" (4m)
Cable
IEC IP66
78.74" (2m)
Fixed
BRP200-DDTN
SENSOR REFLECTIVE 200MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR200-DDTN-C
SENSOR REFLECTIVE 200MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Connector
IEC IP66
-
Adjustable
BR4M-TDTL
SENSOR THROUGH-BEAM 4M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
157.480" (4m)
Cable
IEC IP66
78.74" (2m)
Fixed
BR4M-TDTD-C
SENSOR THROUGH-BEAM 4M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
157.480" (4m)
Connector
IEC IP66
-
Fixed
BR4M-TDTL-P
SENSOR THROUGH-BEAM 4M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
157.480" (4m)
Cable
IEC IP66
78.74" (2m)
Fixed
BRP100-DDT-C-P
SENSOR REFLECTIVE 100MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective, Diffuse
1ms
BR
3.937" (100mm)
Connector
IEC IP66
-
Adjustable
BR20M-TDTD-C
SENSOR THROUGH-BEAM 20M NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Through-Beam
1ms
BR
787.402" (20m)
Connector
IEC IP66
-
Fixed
BR200-DDTN-P
SENSOR, PHOTO, DIFFUSE REFLECTIV
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IP66
78.7" (2000.00mm)
Adjustable
BRP400-DDT
SENSOR REFLECTIVE 400MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective, Diffuse
1ms
BR
15.748" (400mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR200-DDTN-P
SENSOR REFLECTIVE 200MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BRP200-DDTN-P
SENSOR REFLECTIVE 200MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR3M-MDT-P
SENSOR RETROREFLECTIVE 3M PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Retroreflective
1ms
BR
118.110" (3m)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR200-DDTN
SENSOR, PHOTO, DIFFUSE REFLECTIV
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IP66
78.7" (2000.00mm)
Adjustable
BR200-DDTN-C
SENSOR, PHOTO, DIFFUSE REFLECTIV
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Connector
IP66
-
Adjustable
BR200-DDTN
SENSOR REFLECTIVE 200MM NPN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Cable
IEC IP66
78.74" (2m)
Adjustable
BR200-DDTN-C-P
SENSOR REFLECTIVE 200MM PNP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-10°C ~ 60°C (TA)
12V ~ 24V
Reflective
1ms
BR
7.874" (200mm)
Connector
IEC IP66
-
Adjustable

About  Photoelectric, Industrial

Industrial photoelectric sensors are devices used to detect the presence, absence, or distance of objects in industrial applications. These sensors employ fixed wavelengths of light to transmit signals and utilize their receivers to detect changes in the transmitted light. They are designed to ignore ambient light and provide reliable detection in challenging industrial environments. These sensors are housed in rugged cases, making them suitable for use in harsh industrial conditions. They come in various sensing methods, each tailored to specific application requirements. Cross-beam sensors: Consist of separate transmitter and receiver units that create a beam perpendicular to the path of the object being detected. The interruption of the beam triggers the sensor. Through-beam sensors: Comprise a separate transmitter and receiver unit placed opposite each other. An object passing between them interrupts the transmitted beam, triggering the sensor. Diffused sensors: The transmitter and receiver are housed together in a single unit. The sensor detects the reflected light from an object within its sensing range. Reflective sensors: Utilize a reflective surface to direct the transmitted light back to the receiver. The detection occurs when the reflected light is interrupted by the presence or absence of an object. Retroreflective sensors: Deploy a special reflector to bounce the transmitted light back to the receiver. The sensor detects changes in the reflected light caused by an object entering or leaving the sensing zone. Transmissive sensors: Consist of a separate transmitter and receiver unit placed opposite each other, with the object being detected passing through the gap between them. The interruption of the transmitted beam triggers the sensor. Proximity sensors: Designed to detect objects in close proximity without physical contact. They utilize various technologies, such as capacitive, inductive, or magnetic fields, to sense the presence of objects. Distance sensors: Enable precise distance measurement by utilizing techniques like time-of-flight or triangulation. These sensors are commonly used in automated industrial processes. Line focus sensors: Generate a narrow beam of light, allowing for precise detection of objects within a specific line or path. In addition to the sensing methods, industrial photoelectric sensors are differentiated by factors such as light source color and wavelength, sensing distance, ingress protection (IP) rating indicating resistance to dust and moisture, and output configuration. Overall, industrial photoelectric sensors play a vital role in industrial automation, enabling reliable and accurate object detection. They are designed to withstand harsh environments and are available in various configurations to meet different application needs.