WVM Series, Monitor - Relay Output

Results:
13
Manufacturer
Series
Voltage - Supply
Trip Range
Type
Trip Status
Output Type
Delay Time
Circuit
Mounting Type
Contact Rating @ Voltage
Results remaining13
Applied Filters:
WVM
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
WVM911AN
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM011AL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
500 ~ 600V AC
0.25 Sec ~ 30 Sec
500 ~ 600VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM611AH
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
200 ~ 240V AC
0.25 Sec ~ 30 Sec
200 ~ 240VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM611RL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
200 ~ 240V AC
0.25 Sec ~ 30 Sec
200 ~ 240VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM811AH
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
355 ~ 425V AC
0.25 Sec ~ 30 Sec
355 ~ 425VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911AH
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911AL-60
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911RH
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM611AL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
200 ~ 240V AC
0.25 Sec ~ 30 Sec
200 ~ 240VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911RN-60
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM811RL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
355 ~ 425V AC
0.25 Sec ~ 30 Sec
355 ~ 425VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911AL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC
WVM911RL
3 PHASE VOLTAGE MONITOR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
WVM
Voltage Sensing AC, Phase Loss
Energized High/Low
400 ~ 480V AC
0.25 Sec ~ 30 Sec
400 ~ 480VAC
Relay
SPDT (1 Form C)
10A @ 250VAC

About  Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.