LSRU Series, Monitor - Relay Output

Results:
16
Manufacturer
Series
Trip Status
Delay Time
Trip Range
Type
Output Type
Voltage - Supply
Circuit
Mounting Type
Contact Rating @ Voltage
Results remaining16
Applied Filters:
LSRU
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
LSRU-115-AL-2
LOAD SENSOR/ 115V/ 5-25A/ UC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
-
5 ~ 25A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-AL-3
LOAD SENSOR/ 115V/ 25-100A/ UC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
-
25 ~ 100A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-FC-1.5
LOAD SENSOR/115V/0-10A/UC OC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
-
0 ~ 10A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OR-1.5
LOAD SENSOR/ 115V/ 0-10A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High
0 ~ 10A AC
0.5 Sec ~ 300 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OR-2
LOAD SENSOR/ 115V/ 5-25A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High
5 ~ 25A AC
0.5 Sec ~ 300 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OT-1.5
LOAD SENSOR/ 115V/ 0-10A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High
0 ~ 10A AC
0.5 Sec ~ 60 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OT-2
LOAD SENSOR/ 115V/ 5-25A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High
5 ~ 25A AC
0.5 Sec ~ 60 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OT-3
LOAD SENSOR/ 115V/ 25-100A/ OC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High
25 ~ 100A AC
0.5 Sec ~ 60 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OU-1.5
LOAD SENSOR/ 115V/ 0-10A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High/Low
0 ~ 10A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OU-2
LOAD SENSOR/ 115V/ 5-25A/ OC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High/Low
5 ~ 25A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-OU-3
LOAD SENSOR/ 115V/ 25-100A/ OC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized High/Low
25 ~ 100A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-UE-2
LOAD SENSOR/ 115V/ 25-100A/ UC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized Low
5 ~ 25A AC
0.02 Sec ~ 0.3 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-UR-2
LOAD SENSOR/ 115V/ 5-25A/ UC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized Low
5 ~ 25A AC
0.5 Sec ~ 300 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-UT-2
LOAD SENSOR/ 115V/ 5-25A/ UC T
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized Low
5 ~ 25A AC
0.5 Sec ~ 60 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-UT-3
LOAD SENSOR/ 115V/ 25-100A/ UC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
Energized Low
25 ~ 100A AC
0.5 Sec ~ 60 Sec
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC
LSRU-115-AL 1.5
LOAD SENSOR/ 115V/ 0-10A/ UC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
LSRU
Current Sensing AC
-
0 ~ 10A AC
No Delay
115VAC
Relay
SPDT (1 Form C)
10A @ 240VAC

Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.