K8AK Series, Monitor - Relay Output

Results:
34
Manufacturer
Series
Type
Trip Range
Voltage - Supply
Circuit
Delay Time
Trip Status
Output Type
Mounting Type
Contact Rating @ Voltage
Results remaining34
Applied Filters:
K8AK
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
K8AK-TH11S 24VAC/DC
1+
$58.3099
5+
$55.0704
10+
$51.8310
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Temperature Monitoring
-
-
No Delay
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-VW3 24VAC/DC
UNDROVR VOLT RELAY 20 TO 600 V
1+
$357.4648
5+
$337.6056
10+
$317.7465
Quantity
8 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
20 ~ 600V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AS2 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
0.1 ~ 8A AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AW1 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
2 ~ 500mA AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AS3 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
10 ~ 200A AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-TS1 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Temperature Monitoring
-
-
No Delay
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-VS3 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
20 ~ 600V AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-PM1 200/240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Asymmetry, Phase Loss, Phase Sequence
-
-
0.1 Sec ~ 30 Sec
200 ~ 240VAC
Relay
SPDT (1 Form C) x 2
5A @ 250VAC
K8AK-PW2 380/480VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC
-
-
No Delay
380 ~ 480VAC
Relay
SPDT (1 Form C) x 2
5A @ 250VAC
K8AK-VS2 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
1 ~ 150V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-TH12S 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Temperature Monitoring
-
-
No Delay
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AW1 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
2 ~ 500mA AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-TH11S 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Temperature Monitoring
-
-
No Delay
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-PH1 200/500VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Phase Loss, Phase Sequence
-
-
0.1 Sec ~ 30 Sec
200 ~ 480VAC
Relay
DPDT (2 Form C)
5A @ 250VAC
K8AK-VS3 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
20 ~ 600V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-VW2 24VAC/DC
UNDR/OVR VOLT RELAY 1 TO 150 V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
1 ~ 150V AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-VW2 100-240VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Sensing AC/DC
-
1 ~ 150V AC/DC
0.1 Sec ~ 30 Sec
100 ~ 240VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AW2 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
0.1 ~ 8A AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-PA2 380/480VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Voltage Asymmetry, Phase Loss, Phase Sequence
-
-
0.1 Sec ~ 30 Sec
380 ~ 480VAC
Relay
SPDT (1 Form C)
5A @ 250VAC
K8AK-AS1 24VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
DIN Rail
K8AK
Current Sensing AC/DC
-
2 ~ 500mA AC/DC
0.1 Sec ~ 30 Sec
24VAC/DC
Relay
SPDT (1 Form C)
5A @ 250VAC

About  Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.