CR5395 Series, Monitor - Relay Output

Results:
13
Manufacturer
Series
Trip Status
Trip Range
Voltage - Supply
Delay Time
Type
Output Type
Circuit
Mounting Type
Contact Rating @ Voltage
Results remaining13
Applied Filters:
CR5395
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeSeriesTypeTrip StatusTrip RangeDelay TimeVoltage - SupplyOutput TypeCircuitContact Rating @ Voltage
CR5395-EH-24D-110-X-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
No Delay
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EL-24D-110-X-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized Low
1.0 ~ 10A DC
No Delay
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EL-24D-330-B-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized Low
3.0 ~ 30A DC
2 Sec ~ 25 Sec
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EL-24D-330-A-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized Low
3.0 ~ 30A DC
0.5 Sec ~ 6 Sec
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-ACV-110-X-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
No Delay
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-ACV-110-A-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
0.5 Sec ~ 6 Sec
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-ACV-110-B-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
2 Sec ~ 25 Sec
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-24D-110-B-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
2 Sec ~ 25 Sec
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-24D-110-A-CD-ELR-I
RELAY DC CUR SENS 24VDC CHAS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
1.0 ~ 10A DC
0.5 Sec ~ 6 Sec
24VDC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-LL-ACV-110-A-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Latch Low
1.0 ~ 10A DC
0.5 Sec ~ 6 Sec
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EH-ACV-330-X-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized High
3.0 ~ 30A DC
No Delay
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-LH-ACV-101-A-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Latch High
10 ~ 100A DC
0.5 Sec ~ 6 Sec
85 ~ 265VAC/DC
Relay
SPDT (1 Form C)
20A @ 240VAC
CR5395-EL-ACV-330-B-CD-ELR-I
RELAY DC CUR SENS 85-265VAC/DC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Chassis Mount
CR5395
Current Sensing DC
Energized Low
3 ~ 30A DC
2 Sec ~ 25 Sec
85 ~ 265VAC
Relay
SPDT (1 Form C)
20A @ 240VAC

About  Monitor - Relay Output

Relay output monitors are essential devices used to detect and respond to abnormal output from industrial relays. These monitors play a critical role in ensuring the smooth and safe operation of industrial systems by triggering logical outputs or a set of contacts in response to detected anomalies. There are various types of abnormal output that relay output monitors can detect, including AC and DC current or voltage variations, voltage asymmetry, ground faults, temperature abnormalities, phase loss, and sequence or imbalance issues. By detecting these anomalies, the monitors help prevent potential damage to equipment and ensure the safety and efficiency of industrial operations. One key feature of relay output monitors is their selectability, which allows users to configure trip ranges, delay times, supply voltages, mounting types, and switch circuitry according to specific system requirements. This flexibility enables customization to suit the unique needs of different industrial applications, ensuring precise and tailored monitoring and response capabilities. In summary, relay output monitors are crucial components for detecting abnormal output from industrial relays and initiating appropriate responses to maintain the safety and efficiency of industrial systems. Through the detection of various anomalies and customizable features, these monitors are integral to the reliable and effective operation of industrial equipment and processes.