MCR
Select
ImageProduct DetailPriceAvailabilityECAD ModelAccuracySeriesVoltage - SupplyApproval AgencyMounting TypeTermination StyleTypeInput RangeOutputIsolationResponse TimeOperating Temperature
2308043
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 300A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2813499
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 200A
4 ~ 20mA
5000VAC (Test)
340ms
-20°C ~ 60°C
2308072
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 400A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2813460
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 200A
0 ~ 10VDC
5000VAC (Test)
340ms
-20°C ~ 60°C
2813457
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 100A
0 ~ 10VDC, 0 ~ 20mA
5000VAC (Test)
340ms
-20°C ~ 60°C
2813509
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 400A
4 ~ 20mA
5000VAC (Test)
340ms
-20°C ~ 60°C
2814715
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 11A
±10VDC, 0 ~ 20mA
300VAC (Working), 4000VAC (Test)
40ms, 330ms
-20°C ~ 60°C
2814731
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 11A
±10VDC, 0 ~ 20mA
300VAC (Working), 4000VAC (Test)
40ms, 330ms
-20°C ~ 60°C
2308098
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 600A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2308302
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 300A
0 ~ 10VDC
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2811103
TRANSDUCER VOLTAGE 18.5-30.2VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
18.5 ~ 30.2VDC
CE, cULus
DIN Rail
Spring Terminal
AC Voltage Transducer
0 ~ 440VAC
0 ~ 10VDC, 0 ~ 20mA
440VAC (Working), 3300VAC (Test)
-
-25°C ~ 60°C
2811116
TRANSDUCER VOLTAGE 18.5-30.2VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
18.5 ~ 30.2VDC
CE, cULus
DIN Rail
Spring Terminal
DC Voltage Transducer
±660VDC
±10VDC, ±20mA
660VAC (Working), 1500VAC (Test)
12ms
-25°C ~ 50°C
2308108
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 100A
0 ~ 10VDC
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2308030
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 200A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2308085
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
DIN Rail
Spring Terminal
Current Transducer
0 ~ 500A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C
2813486
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 100A
4 ~ 20mA
5000VAC (Test)
340ms
-20°C ~ 60°C
2814728
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 55A
±10VDC, 0 ~ 20mA
300VAC (Working), 4000VAC (Test)
40ms, 330ms
-20°C ~ 60°C
2813473
TRANSDUCER CURRENT 20-30VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
20 ~ 30VDC
CE, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 400A
0 ~ 10VDC
5000VAC (Test)
340ms
-20°C ~ 60°C
2810612
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
ATEX, cULus
DIN Rail
Screw Terminal
Current Transducer
0 ~ 5A
0 ~ 20mA
4000VAC (Test)
-
-20°C ~ 60°C
2308027
TRANSDUCER CURRENT 24VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
MCR
24VDC
CE, cULus
Chassis Mount, DIN Rail
Spring Terminal
Current Transducer
0 ~ 100A
4 ~ 20mA
300VAC (Working), 3500VAC (Test)
150ms
-40°C ~ 65°C

About  Monitor - Current/Voltage Transducer

Industrial current or voltage transducers play a crucial role in monitoring variable or non-sinusoidal power sources, triggering peripheral devices in phase-fired control systems, and overseeing ground current, as well as other voltage or current monitoring applications. These transducers are essential in industrial settings where precise monitoring and control of electrical parameters are necessary. The primary function of industrial current or voltage transducers is to convert electrical signals from one form to another, allowing for accurate measurement and monitoring. They are capable of handling non-sinusoidal and variable sources, making them versatile tools for a wide range of industrial applications. These transducers provide output in the form of analog voltage or current, as well as positive and negative fixed voltages with high accuracy ranging from 0.2% to 2%. This high level of accuracy ensures that the measured values closely align with the actual electrical parameters, providing reliable data for monitoring and control purposes. In phase-fired control systems, industrial current or voltage transducers are used to trigger peripheral devices based on the monitored electrical signals, enabling precise control over power distribution and utilization. Moreover, they can effectively monitor ground current and other critical electrical parameters to ensure safe and efficient operation of industrial equipment and systems. In summary, industrial current or voltage transducers are essential components for monitoring and controlling electrical parameters in industrial environments. Their ability to handle variable or non-sinusoidal sources, along with providing accurate output measurements, makes them indispensable for a wide range of voltage or current monitoring applications in industrial settings.