480:347:277-125VA-IC
XFRMR 347/277V 125VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
347V, 480V
277V
Wire Leads
Wire Leads
125VA
E3H112S
112.5KVA 208D-208Y
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E3
Isolation
208V
-
-
-
-
ES5HF50S
50KVA 240X480-120/240 1P 115C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ES5
-
240V, 480V
-
-
-
-
E5HB75S
75KVA 480D-240DCT 80C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E5
-
480V
-
-
-
-
F81F45S
45KVA 480D-480Y C1D2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Autotransformer (Non-Isolated)
480V
-
-
-
-
DT651H118S
118KVA 460D-460Y SCR DRIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Isolation
-
-
-
-
-
E2H75SCU
75KVA 480D-208Y CU
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E2
Isolation
480V
-
-
-
-
E2HB75S
75KVA 480D-208Y 80C
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
E2
-
480V
-
-
-
-
DT631H93S
93KVA 575D-230Y SCR DRIVE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Isolation
575V
-
-
-
-
289C
TRANSFORMR ISOL 230-115VAC 250VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
289
Isolation
230V
115V
NEMA 5-15P
-
250VA
170D
TRANSFORMR AUTO 115-230VAC 500VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
170
Autotransformer (Non-Isolated)
115V, 230V
115V, 230V
Wire Leads
Wire Leads
500VA
SU-1/2
XFRMR ISO PWR 1/2KVA 1.15/2.3A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
SU
Isolation
104V, 110V, 120V, 208V, 220V, 230V, 240V
208V, 220V, 240V, 416V, 440V, 460V, 480V
Screw Terminal
Screw Terminal
500VA
N-500MG
AUTOTRANSFORMER NON-ISOL 500 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15P
500VA
MD-500-U
MED GRADE ENC ISOLATION XFORMR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MD
Isolation, Medical Grade
120V
120V
NEMA 5-15P
NEMA 5-15R (2)
500VA
172A
TRANSFRMR ISOL 230 TO 115V 100VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
172
Isolation
230V
115V
NEMA 6-15P
NEMA 5-15R
100VA
N-2X
AUTOTRANSFORMER NON-ISOL 100 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
Wire Leads
Wire Leads
100VA
IS500HG
TRANSF ISO 500W 4OUT HOSP GRADE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
IS
Isolation, Medical Grade
120V
120V
NEMA 5-15P
NEMA 5-15R (4)
500VA
MD-1000-U
MED GRADE ENC ISOLATION XFORMR
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
MD
Isolation, Medical Grade
120V
120V
NEMA 5-15P
NEMA 5-15R (2)
1000VA
176G
TRANSFORMER AUTO STEP UP/PLG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
176
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15R
1500VA
171E
TRANSFM ISOL 115 TO 115VAC 500VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
171
Isolation
115V
115V
NEMA 5-15P
NEMA 5-15R
500VA

Isolation Transformers and Autotransformers, Step Up, Step Down

The products within this category are intended to be used in conjunction with AC utility power for various safety or functional purposes. Two common types of transformers in this family are isolation transformers and autotransformers. Isolation transformers are specifically designed to transfer electrical power from one circuit to another without establishing a direct electrical connection. They provide galvanic isolation, which means they prevent the flow of electric current between the input and output circuits. Isolation transformers are frequently utilized in repair or product development environments where the mitigation of shock hazards is crucial. By isolating the circuits, these transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. On the other hand, autotransformers are used for voltage scaling purposes. They can increase or decrease the voltage of an available power source to meet specific functional requirements. Unlike isolation transformers, autotransformers do not provide galvanic isolation between the input and output circuits. Therefore, they are employed when electrical isolation is not necessary. Autotransformers are commonly used in scenarios where voltage conversion is needed, such as stepping up or stepping down the voltage for specific equipment or devices. In summary, products within this category serve different purposes in relation to AC utility power. Isolation transformers are utilized to transfer electrical power without establishing a galvanic connection, ensuring safety by mitigating shock hazards. Autotransformers, on the other hand, are used to scale the voltage of an available source to meet functional requirements when isolation between input and output circuits is unnecessary.