Current Lighting

Current Lighting

Thomas Research Products is a reputable company that specializes in providing advanced LED lighting solutions and power conversion technology. With a strong commitment to innovation, quality, and customer satisfaction, they offer a comprehensive range of products, including LED drivers, surge protectors, emergency lighting systems, and related components. These solutions are designed to deliver exceptional performance, efficiency, and durability for various applications. The company's team of experienced engineers works closely with clients to develop customized solutions that meet their specific requirements. Additionally, Thomas Research Products prioritizes sustainability and environmental responsibility by reducing waste, energy consumption, and offering recycling programs. With a global presence and a strong network of partners, they are a trusted provider of reliable and innovative LED lighting solutions and power conversion technology.

Isolation Transformers and Autotransformers, Step Up, Step Down

Results:
12
Series
Power - Max
Voltage - Secondary
Voltage - Primary
Type
1st Connector
2nd Connector
Results remaining12
Applied Filters:
Current Lighting
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesTypeVoltage - PrimaryVoltage - Secondary1st Connector2nd ConnectorPower - Max
480:347:277-125VA-IC
XFRMR 347/277V 125VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
347V, 480V
277V
Wire Leads
Wire Leads
125VA
480:277-250VA-L
XFRMR 480/277V 250VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Autotransformer (Non-Isolated)
347V, 480V
200V, 277V
Wire Leads
Wire Leads
180VA, 250VA
480:347:277:220-245VA
347/277:220V 245VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
-
-
-
-
-
-
120:277-275VA
TRANSFRMR 120-277V/275VA STEP-UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
-
-
-
-
-
-
120:268:277-500VA-IC
TRANSFRMR 120-277V/500VA STEP-UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
120V
277V
Wire Leads
Wire Leads
500VA
120:268:277-500VA
TRANSFRMR 120-277V/500VA STEP-UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
-
-
-
-
-
-
120/277-275VA-IC
TRANSFRMR 120-277V/275VA STEP-UP
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
120V
277V
Wire Leads
Wire Leads
275VA
480:277-375VA-L
XFRMR 480/277V 375VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Autotransformer (Non-Isolated)
347V, 480V
200V, 277V
Wire Leads
Wire Leads
270VA, 375VA
480:347:277:220-245VA-IC
347/277:220V 245VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
347V, 480V
277V
Wire Leads
Wire Leads
245VA
480:347:277-125VA
XFRMR 347/277V 125VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
-
-
-
-
-
-
480:347:277-460VA-IC
XFRMR 347/277V 460VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
Autotransformer (Non-Isolated)
347V, 480V
277V
Wire Leads
Wire Leads
460VA
480:347:277-460VA
XFRMR 347/277V 460VA STEP-DOWN
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
ATX
-
-
-
-
-
-

About  Isolation Transformers and Autotransformers, Step Up, Step Down

The products within this category are intended to be used in conjunction with AC utility power for various safety or functional purposes. Two common types of transformers in this family are isolation transformers and autotransformers. Isolation transformers are specifically designed to transfer electrical power from one circuit to another without establishing a direct electrical connection. They provide galvanic isolation, which means they prevent the flow of electric current between the input and output circuits. Isolation transformers are frequently utilized in repair or product development environments where the mitigation of shock hazards is crucial. By isolating the circuits, these transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. On the other hand, autotransformers are used for voltage scaling purposes. They can increase or decrease the voltage of an available power source to meet specific functional requirements. Unlike isolation transformers, autotransformers do not provide galvanic isolation between the input and output circuits. Therefore, they are employed when electrical isolation is not necessary. Autotransformers are commonly used in scenarios where voltage conversion is needed, such as stepping up or stepping down the voltage for specific equipment or devices. In summary, products within this category serve different purposes in relation to AC utility power. Isolation transformers are utilized to transfer electrical power without establishing a galvanic connection, ensuring safety by mitigating shock hazards. Autotransformers, on the other hand, are used to scale the voltage of an available source to meet functional requirements when isolation between input and output circuits is unnecessary.