N Series, Isolation Transformers and Autotransformers, Step Up, Step Down

Results:
36
Manufacturer
Series
Power - Max
2nd Connector
Voltage - Secondary
1st Connector
Voltage - Primary
Type
Results remaining36
Applied Filters:
N
Select
ImageProduct DetailPriceAvailabilityECAD ModelSeriesTypeVoltage - PrimaryVoltage - Secondary1st Connector2nd ConnectorPower - Max
N-6U
AUTOTRANSFORMER NON-ISOL 200 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
Wire Leads
Wire Leads
200VA
N-1X
AUTOTRANSFORMER NON-ISOL 50 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
Wire Leads
Wire Leads
50VA
N-51X
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V
115V
Wire Leads
Wire Leads
35VA
N-1000MG
AUTOTRANSFORMER NON-ISOL 1000VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15P
1000VA
N-2X
AUTOTRANSFORMER NON-ISOL 100 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
Wire Leads
Wire Leads
100VA
N-500MG
AUTOTRANSFORMER NON-ISOL 500 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15P
500VA
N-67A
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V, 230V
115V
Wire Leads
Wire Leads
150VA
N-54MG
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V
115V
NEMA 5-15P
NEMA 5-15R
150VA
N-55MG
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V
115V
NEMA 5-15P
NEMA 5-15R
250VA
N-7MG
AUTOTRANSFORMER NON-ISOL 600 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
NEMA 6-15P
NEMA 5-15R
600VA
N-11MG
AUTOTRANSFORMER NON-ISOL 2000 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
120V
NEMA 6-15P
NEMA5-15R
2000VA
N-66A-B
TRANS 250VA 115V 2.17A CHASIS MT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V, 230V
115V
Wire Leads
Wire Leads
250VA
N-92MD
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V
115V
NEMA 5-15P
NEMA 5-15R
500VA
N-259MG
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
230V
115V
NEMA 6-15P
NEMA 5-15R
1000VA
N-9MG
AUTOTRANSFORMER NON-ISOL 1250 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
NEMA 6-15P
NEMA 5-15R
1250VA
N-4MG
AUTOTRANSFORMER NON-ISOL 150 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
230V
115V
NEMA 6-15P
NEMA 5-15P
150VA
N-150MG
AUTOTRANSFORMER NON-ISOL 150 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15P
150VA
N-250MG
AUTOTRANSFORMER NON-ISOL 250 VA
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Autotransformer (Non-Isolated)
115V
230V
NEMA 5-15P
NEMA 6-15P
250VA
N-57MG
TRANSFORMER ISOL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V
115V
NEMA 5-15P
NEMA 5-15R
500VA
N-68X-B
TRANSFORMER ISOL 50VA 115/230VAC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
N
Isolation
115V, 230V
115V
Wire Leads
Wire Leads
50VA

About  Isolation Transformers and Autotransformers, Step Up, Step Down

The products within this category are intended to be used in conjunction with AC utility power for various safety or functional purposes. Two common types of transformers in this family are isolation transformers and autotransformers. Isolation transformers are specifically designed to transfer electrical power from one circuit to another without establishing a direct electrical connection. They provide galvanic isolation, which means they prevent the flow of electric current between the input and output circuits. Isolation transformers are frequently utilized in repair or product development environments where the mitigation of shock hazards is crucial. By isolating the circuits, these transformers ensure that any potential electrical faults or leakage currents do not pose a risk to the user, thereby enhancing overall safety. On the other hand, autotransformers are used for voltage scaling purposes. They can increase or decrease the voltage of an available power source to meet specific functional requirements. Unlike isolation transformers, autotransformers do not provide galvanic isolation between the input and output circuits. Therefore, they are employed when electrical isolation is not necessary. Autotransformers are commonly used in scenarios where voltage conversion is needed, such as stepping up or stepping down the voltage for specific equipment or devices. In summary, products within this category serve different purposes in relation to AC utility power. Isolation transformers are utilized to transfer electrical power without establishing a galvanic connection, ensuring safety by mitigating shock hazards. Autotransformers, on the other hand, are used to scale the voltage of an available source to meet functional requirements when isolation between input and output circuits is unnecessary.