S364 Series, Inrush Current Limiters (ICL)

Results:
25
Manufacturer
Series
R @ 25°C
Current - Steady State Max
Approval Agency
R @ Current
Lead Spacing
Qualification
Tolerance
Grade
Diameter
Results remaining25
Applied Filters:
S364
Select
ImageProduct DetailPriceAvailabilityECAD ModelToleranceApproval AgencyLead SpacingSeriesR @ 25°CCurrent - Steady State MaxDiameterR @ Current
B57364S2109A2
ICL 1 OHM 20% 16A 21MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
UL
0.295" (7.50mm)
S364
1 Ohms
16 A
0.827" (21.00mm)
-
B57364S0509M000
1+
$0.8366
5+
$0.7901
10+
$0.7437
Quantity
17,169 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
5 Ohms
8.5 A
0.827" (21.00mm)
-
B57364S0100M000
1+
$0.8873
5+
$0.8380
10+
$0.7887
Quantity
10,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
10 Ohms
7.5 A
0.827" (21.00mm)
-
B57364S0509M051
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
5 Ohms
8.5 A
0.827" (21.00mm)
73 mOhms
B57364S0209M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
-
S364
2 Ohms
-
0.827" (21.00mm)
-
B57364S0259M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
2.5 Ohms
11 A
0.827" (21.00mm)
-
B57364S0109M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
-
S364
1 Ohms
-
0.827" (21.00mm)
-
B57364S100M54
ICL 10 OHM 20% 7.5A 21MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
10 Ohms
7.5 A
0.827" (21.00mm)
-
B57364S0259M000
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
2.5 Ohms
11 A
0.827" (21.00mm)
-
B57364S0409M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
4 Ohms
9.5 A
0.827" (21.00mm)
59 mOhms
B57364S0109M000
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
1 Ohms
16 A
0.827" (21.00mm)
-
B57364S0209M000
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
2 Ohms
12 A
0.827" (21.00mm)
-
B57364S0121M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
-
S364
120 Ohms
-
0.827" (21.00mm)
-
B57364S0200M000
NTC THERMISTOR ICL S364/20 , M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
0.295" (7.50mm)
S364
-
-
0.827" (21.00mm)
-
B57364S2209A2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
2 Ohms
12 A
0.827" (21.00mm)
-
B57364S2509A2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
CQC, UL, VDE
0.295" (7.50mm)
S364
5 Ohms
8.5 A
0.827" (21.00mm)
-
B57364S0409M000
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
-
S364
4 Ohms
-
0.827" (21.00mm)
-
B57364S0121M000
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
-
S364
120 Ohms
-
0.827" (21.00mm)
-
B57364S0100M051
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
UL
0.295" (7.50mm)
S364
10 Ohms
7.5 A
0.827" (21.00mm)
-
B57364S0160M000
NTC THERMISTOR ICL S364/16 , M
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
±20%
-
0.295" (7.50mm)
S364
16 Ohms
4 A
0.827" (21.00mm)
-

About  Inrush Current Limiters (ICL)

Inrush Current Limiters (ICLs) are components designed to control and limit the initial surge of electric current that occurs when an electrical device is switched on. This surge, known as inrush current, can be significantly higher than the steady-state current required for normal operation. The primary function of ICLs is to protect the electrical circuit and its components from damage caused by the high inrush current. This surge can potentially overload sensitive devices such as power supplies, transformers, and motors, leading to malfunctions or even component failure. By limiting the inrush current, ICLs help ensure the safe and reliable operation of the devices they are installed in. ICLs achieve this by providing a controlled path for the initial surge of current to flow through. They have a specific resistance that regulates the flow of current during the startup phase of the device. This resistance gradually decreases as the current stabilizes, allowing normal operation to continue without any impedance. The specifications of ICLs can vary depending on the application. The steady-state maximum range of current that ICLs can handle typically falls within the range of 100 milliamperes (mA) to 80 Amperes (A). The resistance at current can range from 1 milliohm to 30.3 ohms. Additionally, ICLs come with different lead spacing options, ranging from 0.098 inches to 1.378 inches, to accommodate various circuit designs. Ultimately, Inrush Current Limiters play a critical role in circuit protection by mitigating the risk of overload and damage caused by inrush current. Their ability to control and limit the surge helps ensure the longevity and reliability of electrical devices and systems.