Controllers - Liquid, Level

Results:
629
Manufacturer
Series
Sensitivity
Voltage - Supply
Features
Contact Rating @ Voltage
Operating Temperature
Distance - Control To Sensor (Max)
Contact Form
Termination Style
Type
Output Type
Mounting Type
Results remaining629
Select
ImageProduct DetailPriceAvailabilityECAD ModelFeaturesOperating TemperatureOutput TypeContact Rating @ VoltageMounting TypeSeriesTypeSensitivityDistance - Control To Sensor (Max)Contact FormTermination StyleVoltage - Supply
61F-GP-NL 2KM AC120
CNTRL LIQ LEV 120VAC SOCKETABLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-10°C ~ 55°C
Relay
3A @ 250VAC
Socketable
61F
High/Low Level
0 ~ 1.3kOhm
2km
SPDT (2 Form C)
Plug In, 11 Pin (Octal)
120VAC
61F-GP-NL 4KM AC120
CNTRL LIQ LEV 120VAC SOCKETABLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-10°C ~ 55°C
Relay
3A @ 250VAC
Socketable
61F
High/Low Level
0 ~ 0.5kOhm
4km
SPDT (2 Form C)
Plug In, 11 Pin (Octal)
120VAC
61F-GP-N AC100
CNTRL LIQ LEV 100VAC SOCKETABLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Level Indication
-10°C ~ 55°C
Relay
3A @ 250VAC
Socketable
61F
High/Low Level
0 ~ 4kOhm
1km
SPDT (2 Form C)
Plug In, 11 Pin (Octal)
100VAC
ELC-2-S
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
ELC
High/Low Level
0 ~ 50kOhm
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
240VAC
ELS-2-B
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
ELS
High/Low Level
0 ~ 50kOhm
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
240VAC
ELS-2-A
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
ELS
High/Low Level
0 ~ 100kOhm
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
240VAC
ELS-1-C-N4
CONTROL LIQ LEVEL 120VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
NEMA 4 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
ELS
High/Low Level
0 ~ 25kOhm
-
SPDT (1 Form C)
Quick Connect - 0.250" (6.3mm)
120VAC
LC-R-1-C-N3
CONTROL LIQ LEVEL 120VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, Auxiliary Contactor, NEMA 3 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
120VAC
LC-F-3-C-N3
CONTROL LIQUID LEV 24VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, Auxiliary Contactor, NEMA 3 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
24VAC
LC-R-3-N4
CONTROL LIQUID LEV 24VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, NEMA 4 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
24VAC
LC-R-1-N4
CONTROL LIQ LEVEL 120VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, NEMA 4 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
120VAC
LC-F-2
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
240VAC
LC-R-2-N3
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, NEMA 3 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
240VAC
LC-R-1-N3
CONTROL LIQ LEVEL 120VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, NEMA 3 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
120VAC
LC-R-2-C
CONTROL LIQ LEVEL 240VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, Auxiliary Contactor
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
240VAC
61F-G2P AC100
CNTRL LIQ LEV 100VAC SOCKETABLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Alarm High - Contact
-10°C ~ 55°C
Relay (2)
5A @ 200VAC
Socketable
61F
High/Low Level
0 ~ 4kOhm
1km
SPST-NO (1 Form A), SPDT (1 Form C)
Plug In, 15 Pin (Octal)
100VAC
LC-R-3-C-N4
CONTROL LIQUID LEV 24VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, Auxiliary Contactor, NEMA 4 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
24VAC
61F-G2PH AC100
CNTRL LIQ LEV 100VAC SOCKETABLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Alarm High - Contact
-10°C ~ 55°C
Relay (2)
5A @ 200VAC
Socketable
61F
High/Low Level
0 ~ 4kOhm
1km
SPST-NO (1 Form A), SPDT (1 Form C)
Plug In, 15 Pin (Octal)
100VAC
LC-R-1-C-N4
CONTROL LIQ LEVEL 120VAC CHASSIS
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Adjustable Sensitivity, Auxiliary Contactor, NEMA 4 Rated Enclosure Included
0°C ~ 60°C
Relay
10A @ 120VAC
Chassis Mount
LC
High/Low Level
0 ~ 100kOhm
-
DPDT (2 Form C)
Screw Terminal
120VAC
61F-GN AC110/220
CNTRL LIQ LEV 110/220VAC DINRAIL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-10°C ~ 55°C
Relay
3A @ 200VAC
DIN Rail
61F
High/Low Level
0 ~ 4kOhm
1km
SPDT (2 Form C)
Screw Terminal
110/220VAC

About  Controllers - Liquid, Level

Industrial liquid level controllers are essential devices used in various industrial applications to monitor the level of liquids in tanks and vessels. These controllers can detect constant levels, high or low levels, and leaks in sensing systems. In addition to their primary function of monitoring liquid levels, industrial liquid level controllers also have several other features that enhance their functionality. Adjustable sensitivity is one such feature that allows users to set the level at which the controller triggers an alarm or activates a valve. Built-in timers are another useful feature that enables users to program the controller to activate at specific times or intervals. LED indication lights provide visual feedback on the status of the system, indicating whether the level is normal, low, or high. Filter alerts are yet another essential feature of liquid level controllers. They alert users when the filter needs replacing or cleaning, preventing the build-up of contaminants that could affect the accuracy of the level sensing. Auto shut off valves are also available in some liquid level controllers, enabling users to automate the process of shutting off the flow of liquid when a certain level is reached. This feature helps prevent spills, overflows, and other potential hazards. Solid-state or mechanical contacts are actuated upon detection with contact form variations of DPDT, DPST, SPDT, and SPST functionality. These contact types enable the controller to trigger alarms, activate valves, or perform other functions according to the user's requirements. In summary, industrial liquid level controllers are essential devices used in various industrial applications to monitor the level of liquids in tanks and vessels. They provide constant level, high or low level, and leak detection sensing capabilities, as well as additional features such as adjustable sensitivity, built-in timers, LED indication, filter alerts, and auto shut off valves. The contact form variations of DPDT, DPST, SPDT, and SPST functionality enable the controller to actuate various functions upon detection, making them highly versatile and adaptable to different applications.