Gas Discharge Tube Arresters (GDT)

Results:
4,345
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Package / Case
Impulse Discharge Current (8/20µs)
Tolerance
Mounting Type
Number of Poles
Fail Short
Voltage - Continuous Operating (Max) (MCOV)
Operating Temperature
Form
Approval Agency
Voltage - Protection Rating (VPR)
Current - Discharge (Max) (8/20µS)
Current - Discharge (Nom) (8/20µS)
Type
Voltage - Protection Level (VP) (2416)
Current - Short Circuit Rating (SCRR)
Features
Results remaining4,345
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail ShortPackage / Case
SL1003A090SM
GDT 90V 10KA 3 POLE SMD
1+
$1.5972
5+
$1.5085
10+
$1.4197
Quantity
1,400 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
3
SL1003A
90 V
10000A (10kA)
No
3-SMD Cylinder Square End
2051-35-SM-RPLF
GDT 350V 2KA 2 POLE SMD
1+
$0.5070
5+
$0.4789
10+
$0.4507
Quantity
1,129 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±25%
2
2051
350 V
2000A (2kA)
No
1812 (4532 Metric)
CG2145MS
GDT 145V 20KA 2 POLE SMD
1+
$2.6620
5+
$2.5141
10+
$2.3662
Quantity
1,097 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
CG2
145 V
20000A (20kA)
No
2-SMD Cylinder Square End
SL1021A350R
GDT 350V 10KA 3 POLE TH
1+
$3.7014
5+
$3.4958
10+
$3.2901
Quantity
1,080 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
3
SL1021A
350 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2030-23T-SM-RPLF
GDT 185V 4KA 3 POLE SMD
1+
$2.2817
5+
$2.1549
10+
$2.0282
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
3
2030-xxT-SM
185 V
4000A (4kA)
No
3-SMD Cylinder Square End
2031-42T-SM-RPLF
GDT 360V 1KA 2 POLE SMD
1+
$1.3842
5+
$1.3073
10+
$1.2304
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
2031-xxT-SM
360 V
1000A (1kA)
No
2-SMD Cylinder Square End
PMT809004
GDT 90V 20KA 3 POLE THROUGH HOLE
1+
$1.6479
5+
$1.5563
10+
$1.4648
Quantity
1,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
3
PMT8
90 V
20000A (20kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
GTCA28-362M-R03
GDT 3600V 3KA 2 POLE TH
1+
$5.1089
5+
$4.8251
10+
$4.5413
Quantity
855 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
2
GT
3600 V
3000A (3kA)
No
Axial Cylinder
GTCS36-351M-R10-2
GDT 350V 10KA 3 POLE SMD
1+
$4.4189
5+
$4.1734
10+
$3.9279
Quantity
750 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
3
GT
350 V
10000A (10kA)
No
3-SMD Cylinder Square End
GTCS36-900M-R10-2
GDT 90V 5KA 3 POLE SURFACE MOUNT
1+
$1.5211
5+
$1.4366
10+
$1.3521
Quantity
740 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
3
GT
90 V
5000A (5kA)
No
3-SMD Cylinder Square End
CG75LS
GDT 75V 20KA 2 POLE SMD
1+
$2.0282
5+
$1.9155
10+
$1.8028
Quantity
704 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
CG
75 V
20000A (20kA)
No
Axial Cylinder, Radial SMT Bend
2046-23-C2LF
GDT 230V 10KA 3 POLE TH
1+
$1.6048
5+
$1.5156
10+
$1.4265
Quantity
690 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
230 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
GTCA28-151M-R20
GDT 150V 20KA 2 POLE TH
1+
$3.5239
5+
$3.3282
10+
$3.1324
Quantity
519 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
2
GT
150 V
20000A (20kA)
No
Axial Cylinder
B88069X3820S102
GDT 1300V 10KA 2 POLE TH
1+
$1.0394
5+
$0.9817
10+
$0.9239
Quantity
503 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±15%
2
A71
1300 V
10000A (10kA)
No
Axial Cylinder
CG32.0LTR
GDT 2000V 5KA 2 POLE TH
1+
$0.8873
5+
$0.8380
10+
$0.7887
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
2
CG3
2000 V
5000A (5kA)
No
Axial Cylinder
CG110MSTR
GDT 110V 20KA 2 POLE SMD
1+
$3.4732
5+
$3.2803
10+
$3.0873
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
CG
110 V
20000A (20kA)
No
2-SMD Cylinder Square End
B88069X3881S102
GDT 75V 20KA 2 POLE THROUGH HOLE
1+
$1.2676
5+
$1.1972
10+
$1.1268
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
2
A81
75 V
20000A (20kA)
No
Axial Cylinder
SL1021A200R
GDT 200V 10KA 3 POLE TH
1+
$4.6141
5+
$4.3577
10+
$4.1014
Quantity
500 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
-
3
SL1021A
200 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
SG150
GDT 150V 2KA 2 POLE SMD
1+
$1.6479
5+
$1.5563
10+
$1.4648
Quantity
476 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
SG
150 V
2000A (2kA)
No
1812 (4532 Metric)
CG590MS
GDT 90V 5KA 2 POLE SURFACE MOUNT
1+
$1.0141
5+
$0.9577
10+
$0.9014
Quantity
454 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
CG5
90 V
5000A (5kA)
No
2-SMD Cylinder Square End

Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.