BK2 Series, Gas Discharge Tube Arresters (GDT)

Results:
8
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Tolerance
Package / Case
Fail Short
Impulse Discharge Current (8/20µs)
Number of Poles
Mounting Type
Results remaining8
Applied Filters:
BK2
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail ShortPackage / Case
BK22001002
GDT 200V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
200 V
1000A (1kA)
No
Axial Cylinder
BK23000702
GDT 140V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
1
BK2
140 V
1000A (1kA)
No
Axial Cylinder
BK22002002
GDT 400V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
400 V
1000A (1kA)
No
Axial Cylinder
BK22005002
GDT 1000V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
1000 V
1000A (1kA)
No
Axial Cylinder
BK22001102
GDT 220V 1KA 1 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
220 V
1000A (1kA)
No
Axial Cylinder
BK22002502
GDT 500V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
500 V
1000A (1kA)
No
Axial Cylinder
BK22003002
GDT 600V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
600 V
1000A (1kA)
No
Axial Cylinder
BK22001502
GDT 300V 1KA 1 POLE TH BOX
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
1
BK2
300 V
1000A (1kA)
No
Axial Cylinder

Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.