2046 Series, Gas Discharge Tube Arresters (GDT)

Results:
27
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Package / Case
Fail Short
Mounting Type
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Results remaining27
Applied Filters:
2046
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail ShortPackage / Case
2046-23-C2LF
GDT 230V 10KA 3 POLE TH
1+
$1.6048
5+
$1.5156
10+
$1.4265
Quantity
690 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
230 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-14-C2LF
GDT 145V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
145 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-60-C2LF
GDT 600V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
600 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-40-ALF
GDT 400V 10KA 3 POLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
User Defined
±20%
3
2046
400 V
10000A (10kA)
No
Cylinder No Lead, 3 Terminal
2046-25-ALF
GDT 250V 10KA 3 POLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
User Defined
±20%
3
2046
250 V
10000A (10kA)
No
Cylinder No Lead, 3 Terminal
2046-42-ALF
GDT 420V 10KA 3 POLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
User Defined
±20%
3
2046
420 V
10000A (10kA)
No
Cylinder No Lead, 3 Terminal
2046-09-C2FLF
GDT 90V 10KA 3 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
90 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-14-C2FLF
GDT 145V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
145 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-23-C2FLF
GDT 230V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
230 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-25-C2FLF
GDT 250V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
250 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-35-C2FLF
GDT 350V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
350 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-40-C2FLF
GDT 400V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
400 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-42-C2FLF
GDT 420V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
420 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-47-C2FLF
GDT 470V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
470 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-60-C2FLF
GDT 600V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
600 V
10000A (10kA)
Yes
Axial Cylinder, 3 Lead (Radial Bend)
2046-09-C2LF
GDT 90V 10KA 3 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
90 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-25-C2LF
GDT 250V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
250 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-47-C2LF
GDT 470V 10KA 3 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±20%
3
2046
470 V
10000A (10kA)
No
Axial Cylinder, 3 Lead (Radial Bend)
2046-23-ALF
GDT 230V 10KA 3 POLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
User Defined
±20%
3
2046
230 V
10000A (10kA)
No
Cylinder No Lead, 3 Terminal
2046-14-ALF
GDT 145V 10KA 3 POLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
User Defined
±20%
3
2046
145 V
10000A (10kA)
No
Cylinder No Lead, 3 Terminal

About  Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.