2045 Series, Gas Discharge Tube Arresters (GDT)

Results:
22
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Package / Case
Fail Short
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Mounting Type
Results remaining22
Applied Filters:
2045
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail ShortPackage / Case
2045-09-BT1LF
GDT 90V 10KA 2 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
90 V
10000A (10kA)
No
Axial Cylinder
2045-14-BLF
GDT 145V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
145 V
10000A (10kA)
No
Axial Cylinder
2045-47-BLF
GDT 470V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
470 V
10000A (10kA)
No
Axial Cylinder
2045-07-BT1LF
GDT 75V 10KA 2 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
75 V
10000A (10kA)
No
Axial Cylinder
2045-13-BT1LF
GDT 130V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
130 V
10000A (10kA)
No
Axial Cylinder
2045-25-BT1LF
GDT 250V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
250 V
10000A (10kA)
No
Axial Cylinder
2045-40-BLF
GDT 400V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
400 V
10000A (10kA)
No
Axial Cylinder
2045-07-BLF
GDT 75V 10KA 2 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
75 V
10000A (10kA)
No
Axial Cylinder
2045-23-BLF
GDT 230V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
230 V
10000A (10kA)
No
Axial Cylinder
2045-14-BT1LF
GDT 145V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
145 V
10000A (10kA)
No
Axial Cylinder
2045-25-BLF
GDT 250V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
250 V
10000A (10kA)
No
Axial Cylinder
2045-35-BLF
GDT 350V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
350 V
10000A (10kA)
No
Axial Cylinder
2045-30-BLF
GDT 300V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
300 V
10000A (10kA)
No
Axial Cylinder
2045-35-BT1LF
GDT 350V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
350 V
10000A (10kA)
No
Axial Cylinder
2045-12-BLF
GDT 120V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
120 V
10000A (10kA)
No
Axial Cylinder
2045-13-BLF
GDT 130V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
130 V
10000A (10kA)
No
Axial Cylinder
2045-09-BLF
GDT 90V 10KA 2 POLE THROUGH HOLE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
90 V
10000A (10kA)
No
Axial Cylinder
2045-12-BT1LF
GDT 120V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
120 V
10000A (10kA)
No
Axial Cylinder
2045-23-BT1LF
GDT 230V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
230 V
10000A (10kA)
No
Axial Cylinder
2045-30-BT1LF
GDT 300V 10KA 2 POLE TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Through Hole
±30%
2
2045
300 V
10000A (10kA)
No
Axial Cylinder

About  Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.