2029 Series, Gas Discharge Tube Arresters (GDT)

Results:
14
Manufacturer
Series
Voltage - DC Spark Over (Nom)
Fail Short
Tolerance
Impulse Discharge Current (8/20µs)
Package / Case
Number of Poles
Mounting Type
Results remaining14
Applied Filters:
2029
Select
ImageProduct DetailPriceAvailabilityECAD ModelMounting TypeToleranceNumber of PolesSeriesVoltage - DC Spark Over (Nom)Impulse Discharge Current (8/20µs)Fail ShortPackage / Case
2029-09-SMLF
GDT 90V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
90 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-15-SMLF
GDT 150V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
150 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-23-SMLF
GDT 230V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
230 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-35-SMLF
GDT 350V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
350 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-42-SMLF
GDT 420V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
420 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-15-SM-RPLF
GDT 150V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
150 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-42-SM-RPLF
GDT 420V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
420 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-09-SM-RPLF
GDT 90V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
90 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-23-SM-RPLF
GDT 230V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
230 V
20000A (20kA)
No
2-SMD Cylinder Square End
2029-47-SMLF
GDT 2 POLE SURFACE MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
2029
-
-
-
2-SMD Cylinder Square End
2029-47-SM-RPLF
GDT 2 POLE SURFACE MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
2029
-
-
-
2-SMD Cylinder Square End
2029-60-SMLF
GDT 2 POLE SURFACE MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
2029
-
-
-
2-SMD Cylinder Square End
2029-60-SM-RPLF
GDT 2 POLE SURFACE MOUNT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
-
2
2029
-
-
-
2-SMD Cylinder Square End
2029-35-SM-RPLF
GDT 350V 20KA 2 POLE SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
Surface Mount
±20%
2
2029
350 V
20000A (20kA)
No
2-SMD Cylinder Square End

Gas Discharge Tube Arresters (GDT)

A gas discharge tube (GDT) is a specialized type of electrical protection component that is designed to protect sensitive electronic equipment from voltage spikes and surges. It is typically used in high-voltage applications and is designed to handle large currents and high voltages. The GDT consists of a glass or ceramic tube that is filled with a mixture of inert gases, such as neon, argon, or a combination of both. The tube contains two electrodes at either end and is sealed to prevent the gas from escaping. When a voltage greater than the GDT's rating is applied across the electrodes, the electric field within the tube becomes strong enough to ionize the gas molecules, causing them to release electrons and become conductive. This allows the excess electrical energy to be safely diverted to ground, protecting the connected equipment from damage. GDTs are commonly used in telecommunications equipment, power distribution systems, and other applications where high-voltage surges and transients can pose a risk to sensitive electronics. They are a reliable and effective way to protect against electrical damage and ensure the safe operation of electrical systems.