SFH Series, Fuses

Results:
8
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining8
Applied Filters:
SFH
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeVoltage Rating - ACOperating TemperaturePackage / CaseApproval AgencyResponse TimeVoltage Rating - DCCurrent Rating (Amps)SeriesFuse TypeBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
1206SFH120F/24-2
FUSE BOARD MOUNT 12A 24VDC 1206
1+
$0.1014
5+
$0.0958
10+
$0.0901
Quantity
24,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
UL
Fast Blow
24 V
12 A
SFH
Board Mount (Cartridge Style Excluded)
100A
14
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH200F/24-2
FUSE BOARD MOUNT 20A 24VDC 1206
1+
$0.1014
5+
$0.0958
10+
$0.0901
Quantity
3,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
UL
Fast Blow
24 V
20 A
SFH
Board Mount (Cartridge Style Excluded)
100A
56
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH100F/24-2
FUSE BOARD MOUNT 10A 24VDC 1206
1+
$0.7606
5+
$0.7183
10+
$0.6761
Quantity
2,900 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
UL
Fast Blow
24 V
10 A
SFH
Board Mount (Cartridge Style Excluded)
100A
9
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH120FM/24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 150°C
1206 (3216 Metric)
UL
-
24 V
12 A
SFH
Board Mount (Cartridge Style Excluded)
100A
14
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH150FM/24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 150°C
1206 (3216 Metric)
UL
-
24 V
15 A
SFH
Board Mount (Cartridge Style Excluded)
100A
26
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH200FM/24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 150°C
1206 (3216 Metric)
UL
-
24 V
20 A
SFH
Board Mount (Cartridge Style Excluded)
100A
56
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH100FM/24-2
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 150°C
1206 (3216 Metric)
UL
-
24 V
10 A
SFH
Board Mount (Cartridge Style Excluded)
100A
9
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)
1206SFH150F/24-2
FUSE BOARD MOUNT 15A 24VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
1206 (3216 Metric)
UL
Fast Blow
24 V
15 A
SFH
Board Mount (Cartridge Style Excluded)
100A
26
0.126" L x 0.063" W x 0.046" H (3.20mm x 1.60mm x 1.17mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.