ANM-UL Series, Fuses

Results:
10
Manufacturer
Series
Color
Current Rating (Amps)
Operating Temperature
Melting I²t
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining10
Applied Filters:
ANM-UL
Select
ImageProduct DetailPriceAvailabilityECAD ModelVoltage Rating - ACOperating TemperatureColorResponse TimeVoltage Rating - DCCurrent Rating (Amps)Fuse TypePackage / CaseBreaking Capacity @ Rated VoltageMounting TypeMelting I²tSeriesApproval AgencySize / Dimension
ANM-UL-7.5A
FUSE AUTO 7.5A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Brown
Fast Blow
32 V
7.5 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-30A
FUSE AUTO 30A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Green
Fast Blow
32 V
30 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-15A
FUSE AUTO 15A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Blue
Fast Blow
32 V
15 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-25A
FUSE AUTO 25A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Clear, White
Fast Blow
32 V
25 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-4A
FUSE AUTOMOTIVE 4A 32VDC BLADE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Pink
Fast Blow
32 V
4 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-5A
FUSE AUTOMOTIVE 5A 32VDC BLADE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Tan
Fast Blow
32 V
5 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-3A
FUSE AUTOMOTIVE 3A 32VDC BLADE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Violet
Fast Blow
32 V
3 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-10A
FUSE AUTO 10A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Red
Fast Blow
32 V
10 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-20A
FUSE AUTO 20A 32VDC BLADE MINI
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Yellow
Fast Blow
32 V
20 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)
ANM-UL-2A
FUSE AUTOMOTIVE 2A 32VDC BLADE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Gray
Fast Blow
32 V
2 A
Automotive
Blade, Miniature
1kA
Requires Holder
-
ANM-UL
cURus, ISO, SAE, UL 248
0.472" L x 0.157" W x 0.386" H (12.00mm x 4.00mm x 9.80mm)

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.