314 Series, Fuses

Results:
83
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Mounting Type
Package / Case
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Size / Dimension
Results remaining83
Applied Filters:
314
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorOperating TemperatureResponse TimeVoltage Rating - ACVoltage Rating - DCCurrent Rating (Amps)SeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / DimensionMounting Type
0314020.MXP
FUSE CERM 20A 250VAC 125VDC 3AB
1+
$0.2155
5+
$0.2035
10+
$0.1915
Quantity
5,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
20 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A AC, 10kA DC
631
CE, CSA, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314012.MXP
FUSE CERM 12A 250VAC 125VDC 3AB
1+
$0.2408
5+
$0.2275
10+
$0.2141
Quantity
4,888 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
12 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
570
CE, CSA, K-MARK, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314015.MXP
FUSE CERM 15A 250VAC 125VDC 3AB
1+
$0.5070
5+
$0.4789
10+
$0.4507
Quantity
1,100 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
15 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
292
CE, CSA, K-MARK, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314030.MX52LP
FUSE CERAMIC 30A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
-
30 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
100A
2490
CE, KC, METI, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Through Hole
0314.375M
FUSE CERAMIC 375MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
375 mA
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A AC, 10kA DC
0.05
CSA, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314040.MXP
FUSE CERM 40A 250VAC 150VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
150 V
40 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
1kA AC, 400A DC
22925
CE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314030.HXP
FUSE CERM 30A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
30 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A AC, 400A DC
2490
CE, K-MARK, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314012.VXP
FUSE CERM 12A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
12 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
570
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314020.VXP
FUSE CERM 20A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
20 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
1kA AC, 10kA DC
631
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314.750MXP
FUSE CERAMIC 750MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
750 mA
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A AC, 10kA DC
0.466
CE, CSA, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314.250MXP
FUSE CERAMIC 250MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
250 mA
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A AC, 10kA DC
0.014
CE, CSA, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314.375HXP
FUSE CERAMIC 375MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
375 mA
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A AC, 10kA DC
0.05
CE, CSA, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314.500MXP
FUSE CERAMIC 500MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
500 mA
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A AC, 10kA DC
0.115
CE, CSA, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314004.MXP
FUSE CERM 4A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
4 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
10.4
CE, CSA, K-MARK, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314005.MXP
FUSE CERM 5A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
5 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
26
CE, CSA, K-MARK, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314003.VXP
FUSE CERM 3A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
3 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A AC, 10kA DC
14.6
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314015.VXP
FUSE CERM 15A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
15 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
292
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314008.VXP
FUSE CERM 8A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
8 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
105
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314005.VXP
FUSE CERM 5A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
5 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
26
CE, CSA, KC, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0314007.MXP
FUSE CERM 7A 250VAC 125VDC 3AB
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
250 V
125 V
7 A
314
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A AC, 10kA DC
71
CE, CSA, K-MARK, PSE, UL
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.