MA Series, Fuses

Results:
10
Manufacturer
Series
Current Rating (Amps)
Operating Temperature
Melting I²t
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining10
Applied Filters:
MA
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorCurrent Rating (Amps)Approval AgencyOperating TemperatureResponse TimeVoltage Rating - ACVoltage Rating - DCSeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeMelting I²t
7020.8520
FUSE CERAMIC 1A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
1 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8540
FUSE CERAMIC 4A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
4 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8550
FUSE CERAMIC 6A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
6 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8580
FUSE CERAMIC 20A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
20 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8610
FUSE CERAMIC 40A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
40 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8510
FUSE CERAMIC 500MA 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
500 mA
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8560
FUSE CERAMIC 10A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
10 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8590
FUSE CERAMIC 30A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
30 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8530
FUSE CERAMIC 2A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
2 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-
7020.8570
FUSE CERAMIC 15A 500VAC/250VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
15 A
-
-40°C ~ 55°C
Fast Blow
500 V
250 V
MA
Cartridge, Ceramic
Cartridge, Non-Standard
100kA AC, 10kA DC
0.551" Dia x 1.969" L (14.00mm x 50.00mm)
Requires Holder
-

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.