SinglFuse™ Series, Fuses

Results:
11
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Operating Temperature
Response Time
Approval Agency
Size / Dimension
Voltage Rating - DC
Package / Case
Color
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Voltage Rating - AC
Results remaining11
Applied Filters:
SinglFuse™
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeVoltage Rating - ACOperating TemperatureApproval AgencyPackage / CaseSeriesResponse TimeFuse TypeCurrent Rating (Amps)Voltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
SF-1206SP175L-2-A9
FUSE BOARD MNT 1.75A 63VDC 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-55°C ~ 125°C
cUL, UL
1206 (3216 Metric)
SinglFuse™
Slow Blow
Board Mount (Cartridge Style Excluded)
1.75 A
63 V
100A
1.5
0.122" L x 0.063" W x 0.035" H (3.10mm x 1.60mm x 0.90mm)
SF-0402FR250-2
FUSE 0402 FAST FILM 32V 2.5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
2.5 A
32 V
100A
0.0688
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR500-2
FUSE 0402 FAST FILM 32V 5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
5 A
32 V
100A
0.7218
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR200-2
FUSE 0402 FAST FILM 32V 2A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
2 A
32 V
100A
0.0518
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR315-2
FUSE 0402 FAST FILM 32V 3.15A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
3.15 A
32 V
100A
0.1273
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR100-2
FUSE 0402 FAST FILM 32V 1A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
1 A
32 V
100A
0.0197
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR063-2
FUSE 0402 FAST FILM 32V 0.63A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
630 mA
32 V
100A
0.0079
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR350-2
FUSE 0402 FAST FILM 32V 3.5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
3.5 A
32 V
100A
0.2083
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR150-2
FUSE 0402 FAST FILM 32V 1.5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
1.5 A
32 V
100A
0.0443
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR400-2
FUSE 0402 FAST FILM 32V 4A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
4 A
32 V
100A
0.3072
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)
SF-0402FR300-2
FUSE 0402 FAST FILM 32V 3A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-20°C ~ 105°C
cUL
0402 (1005 Metric)
SinglFuse™
-
Board Mount (Cartridge Style Excluded)
3 A
32 V
100A
0.1616
0.039" L x 0.020" W x 0.014" H (1.00mm x 0.52mm x 0.35mm)

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.