TCA Series, Fuses

Results:
25
Manufacturer
Series
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Mounting Type
Size / Dimension
Package / Case
Operating Temperature
Melting I²t
Response Time
Color
Fuse Type
Voltage Rating - DC
Voltage Rating - AC
Results remaining25
Applied Filters:
TCA
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureResponse TimeVoltage Rating - ACCurrent Rating (Amps)Fuse TypePackage / CaseBreaking Capacity @ Rated VoltageSize / DimensionSeriesMounting TypeMelting I²tApproval Agency
TCA-20A
FUSE CERAMIC 20A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
20 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cURus, UL 248
TCA-P-15A
FUSE CERAMIC 15A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
15 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
750A
0.270" Dia x 1.276" L (6.85mm x 32.40mm)
TCA
Through Hole
-
cULus, UL 248
TCA-630MA
FUSE CERM 630MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
630 mA
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-250MA
FUSE CERM 250MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
250 mA
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-8A
FUSE CERAMIC 8A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
8 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-12A
FUSE CERAMIC 12A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
12 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-1.6A
FUSE CERAMIC 1.6A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
1.6 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-4A
FUSE CERAMIC 4A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
4 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-7A
FUSE CERAMIC 7A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
7 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-1.25A
FUSE CERM 1.25A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
1.25 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-2A
FUSE CERAMIC 2A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
2 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-25A
FUSE CERAMIC 25A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
25 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cURus, UL 248
TCA-P-8A
FUSE CERAMIC 8A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
8 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
200A
0.270" Dia x 1.276" L (6.85mm x 32.40mm)
TCA
Through Hole
-
cULus, UL 248
TCA-1.5A
FUSE CERAMIC 1.5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
1.5 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-800MA
FUSE CERM 800MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
800 mA
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-100MA
FUSE CERM 100MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
100 mA
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-6A
FUSE CERAMIC 6A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
6 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-5A
FUSE CERAMIC 5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
5 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-1A
FUSE CERAMIC 1A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
1 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248
TCA-15A
FUSE CERAMIC 15A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
15 A
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
750A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
TCA
Requires Holder
-
cULus, UL 248

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.