TDC10
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureCurrent Rating (Amps)Approval AgencyResponse TimeSeriesFuse TypeVoltage Rating - ACPackage / CaseBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeMelting I²t
BK1/TDC10-250-R
FUSE GLASS 250MA 1000VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
250 mA
-
Fast Blow
TDC10
Cartridge, Glass
1000 V
3AB, 3AG, 1/4" x 1-1/4"
2.5A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-500-R
FUSE GLASS 500MA 750VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
500 mA
-
Fast Blow
TDC10
Cartridge, Glass
750 V
3AB, 3AG, 1/4" x 1-1/4"
5A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-1-R
FUSE GLASS 1A 350VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1 A
-
Fast Blow
TDC10
Cartridge, Glass
350 V
3AB, 3AG, 1/4" x 1-1/4"
10A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-5-R
FUSE GLASS 5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
5 A
-
Fast Blow
TDC10
Cartridge, Glass
250 V
3AB, 3AG, 1/4" x 1-1/4"
50A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-10-R
FUSE GLASS 10A 100VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
10 A
-
Fast Blow
TDC10
Cartridge, Glass
100 V
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-2-R
FUSE GLASS 2A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
2 A
-
Fast Blow
TDC10
Cartridge, Glass
250 V
3AB, 3AG, 1/4" x 1-1/4"
20A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-25-R
FUSE GLASS 25A 32VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
25 A
-
Fast Blow
TDC10
Cartridge, Glass
32 V
3AB, 3AG, 1/4" x 1-1/4"
250A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-20-R
FUSE GLASS 20A 32VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
20 A
-
Fast Blow
TDC10
Cartridge, Glass
32 V
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-60-R
FUSE GLASS 60MA 1000VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
60 mA
-
Fast Blow
TDC10
Cartridge, Glass
1000 V
3AB, 3AG, 1/4" x 1-1/4"
600mA
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-3-R
FUSE GLASS 3A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
3 A
-
Fast Blow
TDC10
Cartridge, Glass
250 V
3AB, 3AG, 1/4" x 1-1/4"
30A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-
BK1/TDC10-15-R
FUSE GLASS 15A 32VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
15 A
-
Fast Blow
TDC10
Cartridge, Glass
32 V
3AB, 3AG, 1/4" x 1-1/4"
150A
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
Requires Holder
-

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.