TCD Series, Fuses

Results:
17
Manufacturer
Series
Current Rating (Amps)
Approval Agency
Mounting Type
Size / Dimension
Package / Case
Operating Temperature
Melting I²t
Response Time
Color
Fuse Type
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Results remaining17
Applied Filters:
TCD
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureResponse TimeVoltage Rating - ACSeriesFuse TypeCurrent Rating (Amps)Package / CaseBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeMelting I²tApproval Agency
TCD-1.25A
Ceramic-5x20mm (IEC), Slow 1.25A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
1.25 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-1.6A
FUSE CERAMIC 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
1.6 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-1A
FUSE CERAMIC 1A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
1 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-6.3A
FUSE CERAMIC 6.3A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
6.3 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-4A
FUSE CERAMIC 4A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
4 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-315MA
FUSE CERAMIC 315MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
315 mA
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
IEC 60127
TCD-P-3.15A
FUSE CERAMIC 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
3.15 A
5mm x 20mm (Axial)
1.5kA
0.217" Dia x 0.827" L (5.50mm x 21.00mm)
Through Hole
-
cURus, IEC 60127
TCD-12A
FUSE CERAMIC 12A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
12 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
IEC 60127
TCD-15A
FUSE CERAMIC 15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
15 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
IEC 60127
TCD-3.15A
FUSE CERAMIC 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
3.15 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-2.5A
FUSE CERAMIC 2.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
2.5 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-2A
FUSE CERAMIC 2A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
2 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-250MA
FUSE CERAMIC 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
250 mA
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
IEC 60127
TCD-10A
FUSE CERAMIC 10A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
10 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-8A
FUSE CERAMIC 8A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
8 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-5A
FUSE CERAMIC 5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
5 A
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127
TCD-500MA
FUSE CERAMIC 500MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-55°C ~ 125°C
Slow Blow
250 V
TCD
Cartridge, Ceramic
500 mA
5mm x 20mm
1.5kA
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
-
cURus, IEC 60127

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.