SinglFuse™ SF-2410F-T Series, Fuses

Results:
4
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Mounting Type
Size / Dimension
Package / Case
Results remaining4
Applied Filters:
SinglFuse™ SF-2410F-T
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperatureApproval AgencyResponse TimeCurrent Rating (Amps)Package / CaseSeriesFuse TypeVoltage Rating - ACVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
SF-2410F2500T-2
FUSE BRD MNT 25A 65VAC/65DC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
cUL, UL
Fast Blow
25 A
2-SMD, Square End Block
SinglFuse™ SF-2410F-T
Board Mount (Cartridge Style Excluded)
65 V
65 V
50A
246.55
0.240" L x 0.102" W x 0.102" H (6.10mm x 2.59mm x 2.59mm)
SF-2410F1200T-2
FUSE BRD MNT 12A 86VAC/86DC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
cUL, UL
Fast Blow
12 A
2-SMD, Square End Block
SinglFuse™ SF-2410F-T
Board Mount (Cartridge Style Excluded)
86 V
86 V
200A
52.91
0.240" L x 0.102" W x 0.102" H (6.10mm x 2.59mm x 2.59mm)
SF-2410F1500T-2
FUSE BRD MNT 15A 86VAC/86DC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
cUL, UL
Fast Blow
15 A
2-SMD, Square End Block
SinglFuse™ SF-2410F-T
Board Mount (Cartridge Style Excluded)
86 V
86 V
200A
90.9
0.240" L x 0.102" W x 0.102" H (6.10mm x 2.59mm x 2.59mm)
SF-2410F2000T-2
FUSE BRD MNT 20A 65VAC/65DC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
cUL, UL
Fast Blow
20 A
2-SMD, Square End Block
SinglFuse™ SF-2410F-T
Board Mount (Cartridge Style Excluded)
65 V
65 V
50A
140.8
0.240" L x 0.102" W x 0.102" H (6.10mm x 2.59mm x 2.59mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.