S506 Series, Fuses

Results:
144
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Results remaining144
Applied Filters:
S506
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureResponse TimeVoltage Rating - ACSeriesFuse TypeCurrent Rating (Amps)Package / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / DimensionMounting Type
S506-1.25-R
FUSE GLASS 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
1.25 A
5mm x 20mm
35A
10.05
BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK/S506-V-32-R
FUSE GLASS 32MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
32 mA
5mm x 20mm (Axial)
35A
0.0051
BSI, CCC, IMQ, SEMKO, UL, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-40-R
FUSE GLASS 40MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
40 mA
5mm x 20mm (Axial)
35A
0.0072
BSI, CCC, IMQ, SEMKO, UL, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-80-R
FUSE GLASS 80MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
80 mA
5mm x 20mm (Axial)
35A
0.038
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-63-R
FUSE GLASS 63MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
63 mA
5mm x 20mm (Axial)
35A
0.021
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-8-R
FUSE GLASS 8A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
8 A
5mm x 20mm
80A
255.8
BSI, CSA, cULus, IMQ, PSE/JET, SEMKO, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK1/S506B-3.15R
FUSE GLASS 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
3.15 A
5mm x 20mm
35A
96.4
cURus, PSE/JET, UR
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK/S506-1.6-R
FUSE GLASS 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
1.6 A
5mm x 20mm
35A
21.7
BSI, CCC, CSA, CURUS, IMQ, PSE/JET, SEMKO, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK/S506-125-R
FUSE GLASS 125MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
125 mA
5mm x 20mm
35A
0.063
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK/S506-250-R
FUSE GLASS 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
250 mA
5mm x 20mm
35A
0.265
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
S506-40-R
FUSE GLASS 40MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
40 mA
5mm x 20mm
35A
0.0072
BSI, CCC, IMQ, SEMKO, UL, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
S506-50-R
FUSE GLASS 50MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
50 mA
5mm x 20mm
35A
0.0095
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
S506-63-R
FUSE GLASS 63MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
63 mA
5mm x 20mm
35A
0.021
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
S506-80-R
FUSE GLASS 80MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
80 mA
5mm x 20mm
35A
0.038
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
BK/S506-V-125-R
FUSE GLASS 125MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
125 mA
5mm x 20mm (Axial)
35A
0.063
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-200-R
FUSE GLASS 200MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
200 mA
5mm x 20mm (Axial)
35A
0.114
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-160-R
FUSE GLASS 160MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
160 mA
5mm x 20mm (Axial)
35A
0.093
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-250-R
FUSE GLASS 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
250 mA
5mm x 20mm (Axial)
35A
0.265
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-400-R
FUSE GLASS 400MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
400 mA
5mm x 20mm (Axial)
35A
0.872
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole
BK/S506-V-315-R
FUSE GLASS 315MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Slow Blow
250 V
S506
Cartridge, Glass
315 mA
5mm x 20mm (Axial)
35A
0.621
BSI, CCC, CSA, IMQ, SEMKO, UR, VDE
0.218" Dia x 0.831" L (5.54mm x 21.10mm)
Through Hole

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.