NANO²® 885 Series, Fuses

Results:
8
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Voltage Rating - DC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Results remaining8
Applied Filters:
NANO²® 885
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeVoltage Rating - ACOperating TemperatureResponse TimeVoltage Rating - DCPackage / CaseApproval AgencySeriesFuse TypeCurrent Rating (Amps)Breaking Capacity @ Rated VoltageMelting I²tSize / Dimension
08853.15DR
FUSE BOARD MNT 3.15A 500VDC SMT
1+
$3.8028
5+
$3.5915
10+
$3.3803
Quantity
10 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
3.15 A
100A
13.35
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
088502.5DR
FUSE BOARD MNT 2.5A 500VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
2.5 A
100A
6.9
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
08851.25DR
FUSE BOARD MNT 1.25A 500VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
1.25 A
100A
1.25
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
088501.6DR
FUSE BOARD MNT 1.6A 500VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
1.6 A
100A
2.3
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
0885001.DR
FUSE BOARD MNT 1A 500VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
1 A
100A
0.8
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
0885004.DR
FUSE BOARD MNT 4A 450VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
450 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
4 A
100A
21.3
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
0885002.DR
FUSE BOARD MNT 2A 500VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
500 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
2 A
100A
4.7
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)
0885005.DR
FUSE BOARD MNT 5A 450VDC SMT
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
-40°C ~ 85°C
-
450 V
2-SMD, Square End Block
cURus, TUV
NANO²® 885
Board Mount (Cartridge Style Excluded)
5 A
100A
35
0.428" L x 0.188" W x 0.188" H (10.86mm x 4.78mm x 4.78mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.