MDQ Series, Fuses

Results:
97
Manufacturer
Series
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Operating Temperature
Melting I²t
Response Time
Color
Fuse Type
Voltage Rating - DC
Results remaining97
Applied Filters:
MDQ
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureMounting TypeCurrent Rating (Amps)Approval AgencyResponse TimeVoltage Rating - ACSeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageSize / DimensionMelting I²t
BK/MDQ-V-3
FUSE GLASS 3A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
3 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
100A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
BK/MDQ-5
FUSE GLASS 5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
5 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-4
FUSE GLASS 4A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
4 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-6
FUSE GLASS 6A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
6 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
200A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-9
FUSE GLASS 9A 32VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
9 A
CSA, UL
Slow Blow
32 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
1kA
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-3/8
FUSE GLASS 375MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
375 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-3/10
FUSE GLASS 300MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
300 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-V-1/4
FUSE GLASS 250MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
250 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
35A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
BK/MDQ-V-7
FUSE GLASS 7A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
7 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
200A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
BK/MDQ-V-3/4
FUSE GLASS 750MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
750 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
35A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
BK/MDQ-8
FUSE GLASS 8A 32VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
8 A
CSA, UL
Slow Blow
32 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
1kA
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-V-2
FUSE GLASS 2A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
2 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
100A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
BK/MDQ-V-1-1/2
FUSE GLASS 1.5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Through Hole
1.5 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4" (Axial)
100A
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
-
MDQ-2/10
BUSS SMALL DIMENSION FUSE
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
200 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-8/10
FUSE GLASS 800MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
800 mA
-
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
-
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-7/10
FUSE GLASS 700MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
700 mA
-
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
-
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-3/4
FUSE GLASS 750MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
750 mA
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
35A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-1-8/10
FUSE GLASS 1.8A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
1.8 A
-
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
-
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-1-1/4
FUSE GLASS 1.25A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
1.25 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-
BK/MDQ-1-1/2
FUSE GLASS 1.5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
Requires Holder
1.5 A
CSA, UL
Slow Blow
250 V
MDQ
Cartridge, Glass
3AB, 3AG, 1/4" x 1-1/4"
100A
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
-

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.