C519 Series, Fuses

Results:
40
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Size / Dimension
Package / Case
Results remaining40
Applied Filters:
C519
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureCurrent Rating (Amps)Approval AgencyResponse TimeVoltage Rating - ACSeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionMounting Type
BK/C519-4-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
4 A
UL
Slow Blow
125 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
400A
233.346
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-250-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
250 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
0.467
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-750-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
750 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
9.162
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-7-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
7 A
UL
Slow Blow
125 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
-
-
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-1.25-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1.25 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
22.961
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-1.6-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1.6 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
31.156
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-2.25-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
2.25 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
97.724
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-3.5-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
3.5 A
UL
Slow Blow
125 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
400A
149.279
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-350-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
350 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
1.169
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-375-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
375 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
1.531
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-600-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
600 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
6.982
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-1.5-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1.5 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
31.989
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-5-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
5 A
UL
Slow Blow
125 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
400A
354.813
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-3-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
3 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
80.426
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK1/C519-2.5-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
2.5 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
78.163
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK1/C519-3-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
3 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
80.426
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-1-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
14.289
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-500-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
500 mA
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
35A
2.28
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-2-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
2 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
60.256
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder
BK/C519-2.5-R
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
2.5 A
CSA, UL
Slow Blow
250 V
C519
Cartridge, Glass
2AG, 5mm x 15mm
100A
78.163
0.205" Dia x 0.571" L (5.20mm x 14.50mm)
Requires Holder

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.