C2Q Series, Fuses

Results:
14
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Results remaining14
Applied Filters:
C2Q
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperaturePackage / CaseApproval AgencyResponse TimeVoltage Rating - DCCurrent Rating (Amps)SeriesFuse TypeVoltage Rating - ACBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
C2Q 5
FUSE BOARD MNT 5A 32VAC/VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
32 V
5 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
50A
1.05
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 500
FUSE BOARD MNT 500MA 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
500 mA
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.00015
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 250
FUSE BOARD MNT 250MA 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
250 mA
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
1E-05
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 1.5
FUSE BOARD MNT 1.5A 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
1.5 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.084
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 1
FUSE BRD MNT 1A 32VAC 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
1 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.036
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 750
FUSE BOARD MNT 750MA 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
750 mA
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.02
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 1.25
FUSE BOARD MNT 1.25A 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
1.25 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.058
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 2.5
FUSE BOARD MNT 2.5A 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
2.5 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.24
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 2
FUSE BRD MNT 2A 32VAC 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
2 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.0063
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 4
FUSE BRD MNT 4A 32VAC 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
4 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.63
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 3
FUSE BRD MNT 3A 32VAC 63VDC 0603
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
3 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.36
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 300
FUSE BOARD MNT 300MA 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
300 mA
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.003
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 375
FUSE BOARD MNT 375MA 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
375 mA
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.005
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)
C2Q 3.5
FUSE BOARD MNT 3.5A 32VAC 63VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
0603 (1608 Metric)
CE, cURus
Fast Blow
63 V
3.5 A
C2Q
Board Mount (Cartridge Style Excluded)
32 V
35A AC, 50A DC
0.5
0.063" L x 0.032" W x 0.019" H (1.60mm x 0.82mm x 0.48mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.