C1F Series, Fuses

Results:
16
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining16
Applied Filters:
C1F
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeCurrent Rating (Amps)Operating TemperaturePackage / CaseResponse TimeVoltage Rating - ACSeriesFuse TypeVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / Dimension
C1F 1
FUSE 1.0A 125VAC FAST 1206
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
1 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.012
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 2.5
FUSE 2.5A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
2.5 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.156
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 500
FUSE 500MA 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
500 mA
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.0015
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 2
FUSE 2.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
2 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.085
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 8
FUSE 8.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
8 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
35A AC, 50A DC
3.584
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 5
FUSE 5.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
5 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.83
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 3
FUSE 3.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
3 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.19
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 750
FUSE 750MA 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
750 mA
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.0051
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 4
FUSE 4.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
4 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.336
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 250
FUSE 250MA 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
250 mA
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.0002
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 7
FUSE 7.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
7 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
35A AC, 50A DC
2.283
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 6
FUSE 6.0A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
6 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
1.404
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 1.25
FUSE 1.25A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
1.25 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.023
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 1.5
FUSE 1.5A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
1.5 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.04
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 3.5
FUSE 3.5A 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
3.5 A
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.218
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)
C1F 375
FUSE 375MA 125VAC FAST 1206
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
375 mA
-55°C ~ 125°C
1206 (3216 Metric)
Fast Blow
125 V
C1F
Board Mount (Cartridge Style Excluded)
63 V
100A AC, 50A DC
0.0007
AEC-Q200, cURus
0.126" L x 0.062" W (3.20mm x 1.58mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.