BS88 Series, Fuses

Results:
10
Manufacturer
Series
Current Rating (Amps)
Melting I²t
Breaking Capacity @ Rated Voltage
Response Time
Approval Agency
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Operating Temperature
Color
Fuse Type
Voltage Rating - DC
Results remaining10
Applied Filters:
BS88
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureCurrent Rating (Amps)Approval AgencyResponse TimeSeriesFuse TypeVoltage Rating - ACPackage / CaseBreaking Capacity @ Rated VoltageSize / DimensionMounting TypeMelting I²t
059-0110
FUSE CERAMIC 2A 440VAC 3AB 3AG
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-
-
2 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
011-9926
FUSE CERAMIC 15A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
15 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
-
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
1620
059-0109
FUSE CERAMIC 1A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
1 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
011-9925
FUSE CERAMIC 10A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
10 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
-
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
404
059-0108
FUSE CERM 500MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
500 mA
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
BK3/GBHV12.5A6F
FUSE CERM 12.5A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
12.5 A
UL
Slow Blow
BS88
Cartridge, Ceramic
500 V
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
0.266" Dia x 1.292" L (6.76mm x 32.82mm)
Through Hole
20
059-0107
FUSE CERM 250MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
250 mA
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
059-0112
FUSE CERAMIC 5A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
5 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
059-0111
FUSE CERAMIC 3A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
3 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-
059-0113
FUSE CERAMIC 7A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
7 A
-
-
BS88
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
33kA
0.251" Dia x 1.262" L (6.37mm x 32.05mm)
Requires Holder
-

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.