BRICK 1025TD Series, Fuses

Results:
14
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining14
Applied Filters:
BRICK 1025TD
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperatureCurrent Rating (Amps)Approval AgencyResponse TimeVoltage Rating - ACVoltage Rating - DCPackage / CaseSeriesFuse TypeBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
TR2/1025TD4-R
FUSE BOARD MNT 4A 250VAC 125VDC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
4 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
66.96
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD1.5-R
FUSE BRD MNT 1.5A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
1.5 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
11.79
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD500-R
FUSE BRD MNT 500MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
500 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
1.47
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD3-R
FUSE BOARD MNT 3A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
3 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
42.74
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD3.5-R
FUSE BRD MNT 3.5A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
3.5 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
43.33
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD5-R
FUSE BOARD MNT 5A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
5 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
88.38
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD250-R
FUSE BRD MNT 250MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
250 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
0.128
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD1-R
FUSE BOARD MNT 1A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
1 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
9.91
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD2-R
FUSE BOARD MNT 2A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
2 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
17.27
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD2.5-R
FUSE BRD MNT 2.5A 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
2.5 A
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
16.51
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD750MA
FUSE BRD MNT 750MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
750 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
0.93
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD250MA
FUSE BRD MNT 250MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
250 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
0.128
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD500MA
FUSE BRD MNT 500MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
500 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
1.47
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)
TR2/1025TD750-R
FUSE BRD MNT 750MA 250VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-
750 mA
CSA, UL
Slow Blow
250 V
125 V
2-SMD, Square End Block
BRICK 1025TD
Board Mount (Cartridge Style Excluded)
50A
0.93
0.405" L x 0.109" W x 0.109" H (10.29mm x 2.77mm x 2.77mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.