5HT 100-R
FUSE CERAMIC 100MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
100 mA
-
Slow Blow
5HT
-
5mm x 20mm
-
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
-
5HT 630-R
FUSE CERAMIC 630MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
630 mA
CCC, CE, CSA, cULus
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
0.7
5HT 800-R
FUSE CERAMIC 800MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
800 mA
CCC, CE, CSA, cULus
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
1.1
5HT 1.6-R
FUSE CERAMIC 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
1.6 A
CCC, CE, CSA, cURus, IMQ, PSE, SEMKO, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
5.4
5HT 500-R
FUSE CERAMIC 500MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
500 mA
CCC, CE, CSA, cULus
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
0.46
5HT 315-R
FUSE CERAMIC 315MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
315 mA
CCC, CSA, cURus
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
0.22
5HT 200-R
FUSE CERAMIC 200MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
-
200 mA
-
Slow Blow
5HT
-
5mm x 20mm
-
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Holder
-
5HT 3.15-R
FUSE CERAMIC 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
3.15 A
CCC, CE, CSA, cURus, IMQ, PSE, SEMKO, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
31
5HT 6.3-R
FUSE CERAMIC 6.3A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
6.3 A
CCC, CE, CSA, cURus, SEMKO, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
181
5HT 4-R
FUSE CERAMIC 4A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
4 A
CCC, CE, CSA, cURus, IMQ, PSE, SEMKO, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
56
5HT 1.25-R
FUSE CERAMIC 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
1.25 A
CCC, CE, CSA, cURus, IMQ, PSE, SEMKO, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
3
5HT 8-R
FUSE CERAMIC 8A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
8 A
CE, CSA, cURus
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
330
5HT 1
FUSE CERAMIC 1A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
1 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
1.7
5HT 1.25
FUSE CERAMIC 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
1.25 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
3
5HT 1.6
FUSE CERAMIC 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
1.6 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
5.4
5HT 2
FUSE CERAMIC 2A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
2 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
9.7
5HT 2.5
FUSE CERAMIC 2.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
2.5 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
17.4
5HT 3.15
FUSE CERAMIC 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
3.15 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
31
5HT 4
FUSE CERAMIC 4A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
4 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
56
5HT 5
FUSE CERAMIC 5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
250 V
-
-55°C ~ 125°C
5 A
CCC, CE, CSA, IMQ, PSE, SEMKO, UL, VDE
Slow Blow
5HT
Cartridge, Ceramic
5mm x 20mm
1.5kA
0.201" Dia x 0.787" L (5.10mm x 20.00mm)
Requires Holder
101

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.