527 Series, Fuses

Results:
3
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Package / Case
Results remaining3
Applied Filters:
527
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperatureResponse TimeVoltage Rating - ACVoltage Rating - DCCurrent Rating (Amps)Approval AgencySeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
0527030.UXTHP
FUSE 500VAC 30A PCB TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Fast Blow
500 V
500 V
30 A
cURus
527
Cartridge, Ceramic
Radial Bend Cylinder
10kA
700
0.293" Dia x 1.352" L (7.45mm x 34.35mm)
0527040.UXTHP
FUSE 500VAC 40A PCB TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Fast Blow
500 V
500 V
40 A
cURus
527
Cartridge, Ceramic
Radial Bend Cylinder
10kA
1090
0.293" Dia x 1.352" L (7.45mm x 34.35mm)
0527050.UXTHP
FUSE 305VAC 50A PCB TH
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
-55°C ~ 125°C
Fast Blow
305 V
305 V
50 A
cURus
527
Cartridge, Ceramic
Radial Bend Cylinder
10kA
2460
0.293" Dia x 1.352" L (7.45mm x 34.35mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.