0514002.MXP
FUSE CERAMIC 2A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
4.12
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0514016.MXEP
FUSE 500VAC 3AB PB-FREE 16A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
16 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
-
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514016.MXP
FUSE 500VAC 3AB PB-FREE 16A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
16 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
-
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0514005.MXP
FUSE CERAMIC 5A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
5 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
6.14
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
05143.15MXEP
FUSE 500VAC 3AB 3.15A AXL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
5.54
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514010.MXEP
FUSE CERAMIC 10A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
10 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
50.6
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
051406.3MXP
FUSE CERAMIC 6.3A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
6.3 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
13.5
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0514010.MXP
FUSE CERAMIC 10A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
10 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
50.6
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
051401.6MXP
FUSE CERAMIC 1.6A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.6 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
1.92
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0514008.MXP
FUSE CERAMIC 8A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
8 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
28.8
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
0514004.MXEP
FUSE CERAMIC 4A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
4 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
12.43
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514002.MXEP
FUSE CERAMIC 2A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
4.12
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
051401.6MXEP
FUSE CERAMIC 1.6A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.6 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
1.92
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514008.MXEP
FUSE CERAMIC 8A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
8 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
28.8
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514005.MXEP
FUSE CERAMIC 5A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
5 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
6.14
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
051406.3MXEP
FUSE CERAMIC 6.3A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
6.3 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
13.5
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
0514004.MXP
FUSE CERAMIC 4A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
4 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
12.43
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
05143.15MXP
FUSE 500VAC 3AB 3.15A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
5.54
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder
051412.5MXEP
FUSE CERM 12.5A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
12.5 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4" (Axial)
5kA
114
0.275" Dia x 1.288" L (6.99mm x 32.72mm)
Through Hole
051412.5MXP
FUSE CERM 12.5A 500VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
12.5 A
-55°C ~ 125°C
CE, cURus
Fast Blow
500 V
514
Cartridge, Ceramic
3AB, 3AG, 1/4" x 1-1/4"
5kA
114
0.250" Dia x 1.250" L (6.35mm x 31.75mm)
Requires Holder

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.