3SB Series, Fuses

Results:
52
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Package / Case
Results remaining52
Applied Filters:
3SB
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorOperating TemperatureMounting TypeResponse TimeVoltage Rating - ACSeriesFuse TypeCurrent Rating (Amps)Package / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / DimensionVoltage Rating - DC
3SB 80
FUSE GLASS 80MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Holder
Slow Blow
250 V
3SB
Cartridge, Glass
80 mA
3AB, 3AG, 1/4" x 1-1/4"
35A
0.13
CE, CSA, PSE, UL
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 80-R
FUSE GLASS 80MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Holder
Slow Blow
250 V
3SB
Cartridge, Glass
80 mA
3AB, 3AG, 1/4" x 1-1/4"
200A
0.13
CE, CSA, cULus
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 160-R
FUSE GLASS 160MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Holder
Slow Blow
250 V
3SB
Cartridge, Glass
160 mA
3AB, 3AG, 1/4" x 1-1/4"
200A
0.5
CE, CSA, cULus
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 1.6-R
FUSE GLASS 1.6A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
1.6 A
3AB, 3AG, 1/4" x 1-1/4"
200A
39
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 15-R
FUSE GLASS 15A 125VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
125 V
3SB
Cartridge, Glass
15 A
3AB, 3AG, 1/4" x 1-1/4"
10kA
2123
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 12-R
FUSE GLASS 12A 125VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
125 V
3SB
Cartridge, Glass
12 A
3AB, 3AG, 1/4" x 1-1/4"
10kA
1277
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 750-R
FUSE GLASS 750MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
750 mA
3AB, 3AG, 1/4" x 1-1/4"
200A
9
CE, CSA, cURus
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 500-R
FUSE GLASS 500MA 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
500 mA
3AB, 3AG, 1/4" x 1-1/4"
200A
4.43
CE, CSA, cULus
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 2-R
FUSE GLASS 2A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
2 A
3AB, 3AG, 1/4" x 1-1/4"
200A
61
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 3-R
FUSE GLASS 3A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
3 A
3AB, 3AG, 1/4" x 1-1/4"
200A
146
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 6-R
FUSE GLASS 6A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
6 A
3AB, 3AG, 1/4" x 1-1/4"
200A
286
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 10-R
FUSE GLASS 10A 125VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
125 V
3SB
Cartridge, Glass
10 A
3AB, 3AG, 1/4" x 1-1/4"
10kA
817
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 7-R
FUSE GLASS 7A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
7 A
3AB, 3AG, 1/4" x 1-1/4"
200A
372
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 8-R
FUSE GLASS 8A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
8 A
3AB, 3AG, 1/4" x 1-1/4"
200A
483
CE, CSA, cURus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 5-R
FUSE GLASS 5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
5 A
3AB, 3AG, 1/4" x 1-1/4"
200A
349
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 1.25-R
FUSE GLASS 1.25A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
1.25 A
3AB, 3AG, 1/4" x 1-1/4"
200A
25.4
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 1-R
FUSE GLASS 1A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
1 A
3AB, 3AG, 1/4" x 1-1/4"
200A
16.4
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 2.5-R
FUSE GLASS 2.5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
2.5 A
3AB, 3AG, 1/4" x 1-1/4"
200A
94
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 4-R
FUSE GLASS 4A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
4 A
3AB, 3AG, 1/4" x 1-1/4"
200A
226
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-
3SB 1.5-R
FUSE GLASS 1.5A 250VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Requires Holder
Slow Blow
250 V
3SB
Cartridge, Glass
1.5 A
3AB, 3AG, 1/4" x 1-1/4"
200A
-
CE, CSA, cULus, PSE
0.250" Dia x 1.252" L (6.35mm x 31.80mm)
-

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.