356 Series, Fuses

Results:
16
Manufacturer
Series
Current Rating (Amps)
Melting I²t
Approval Agency
Operating Temperature
Response Time
Color
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining16
Applied Filters:
356
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureApproval AgencyCurrent Rating (Amps)Response TimeSeriesFuse TypeVoltage Rating - ACPackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionMounting Type
35621000029
FUSE CERAMIC 10A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
10 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
510
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35606300029
FUSE CERM 630MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE
630 mA
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
2
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35605000029
FUSE CERM 500MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE
500 mA
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
0.53
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35615000029
FUSE CERAMIC 5A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
5 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
91
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35618000029
FUSE CERAMIC 8A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
8 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
240
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35604000029
FUSE CERM 400MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE
400 mA
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
0.16
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35614000029
FUSE CERAMIC 4A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
4 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
62
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35616300029
FUSE CERAMIC 6.3A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cURus
6.3 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
130
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35611000029
FUSE CERAMIC 1A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
1 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
4.4
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35612000029
FUSE CERAMIC 2A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
2 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
9.2
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35611250029
FUSE CERM 1.25A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
1.25 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
3.1
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35612500029
FUSE CERAMIC 2.5A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
2.5 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
22
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35611600029
FUSE CERAMIC 1.6A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
1.6 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
8.3
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35613150029
FUSE CERM 3.15A 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE, cULus
3.15 A
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
36
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35602000029
FUSE CERM 200MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE
200 mA
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
0.14
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder
35608000029
FUSE CERM 800MA 440VAC 3AB 3AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
CE
800 mA
Slow Blow
356
Cartridge, Ceramic
440 V
3AB, 3AG, 1/4" x 1-1/4"
1kA
3.1
0.248" Dia x 1.260" L (6.30mm x 32.00mm)
Requires Holder

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.