233 Series, Fuses

Results:
101
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Mounting Type
Size / Dimension
Package / Case
Operating Temperature
Response Time
Color
Fuse Type
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Results remaining101
Applied Filters:
233
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCCurrent Rating (Amps)Operating TemperatureVoltage Rating - ACSeriesFuse TypeResponse TimePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / DimensionMounting Type
023301.6MXW
FUSE GLASS 1.6A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.6 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
6.31
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023302.5M
FUSE GLASS 2.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
17.5
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023302.5MXE
FUSE GLASS 2.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
17.5
CSA, K-MARK, METI, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
023302.5MXW
FUSE GLASS 2.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
17.5
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023303.5M
FUSE GLASS 3.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
37.3
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023303.5MXE
FUSE GLASS 3.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
37.3
CSA, K-MARK, METI, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
023303.5MXW
FUSE GLASS 3.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
37.3
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023306.3M
FUSE GLASS 6.3A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
6.3 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
156
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
023306.3MXE
FUSE GLASS 6.3A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
6.3 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
156
CSA, K-MARK, METI, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
023306.3MXW
FUSE GLASS 6.3A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
6.3 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
156
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
02331.25M
FUSE GLASS 1.25A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.25 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
3.48
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
02331.25MXE
FUSE GLASS 1.25A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.25 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
3.48
CSA, K-MARK, METI, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
02331.25MXW
FUSE GLASS 1.25A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
1.25 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
3.48
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
02333.15M
FUSE GLASS 3.15A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
30.6
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
02333.15MXE
FUSE GLASS 3.15A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
30.6
CSA, K-MARK, METI, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
02333.15MXW
FUSE GLASS 3.15A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
30.6
CSA, K-MARK, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
0233010.MXBP
FUSE GLASS 10A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
10 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
274.115
CE, CSA, PSE, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
0233005.MRET1P
FUSE GLASS 5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
89.975
CE, CSA, KC, PSE, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
023302.5MRET1P
FUSE GLASS 2.5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
2.5 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
17.045
CE, CSA, KC, PSE, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole
02333.15MRET1P
FUSE GLASS 3.15A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
3.15 A
-55°C ~ 125°C
125 V
233
Cartridge, Glass
Medium Blow
5mm x 20mm (Axial)
10kA
29.795
CE, CSA, KC, PSE, UL
0.228" Dia x 0.886" L (5.80mm x 22.50mm)
Through Hole

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.