208 Series, Fuses

Results:
51
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Mounting Type
Approval Agency
Voltage Rating - DC
Package / Case
Operating Temperature
Response Time
Color
Fuse Type
Breaking Capacity @ Rated Voltage
Size / Dimension
Voltage Rating - AC
Results remaining51
Applied Filters:
208
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCMounting TypeCurrent Rating (Amps)Operating TemperatureResponse TimeSeriesFuse TypeVoltage Rating - ACPackage / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / Dimension
020801.5MXEP
FUSE GLASS 1.5A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Through Hole
1.5 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm (Axial)
100A
0.8
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208.375MXP
FUSE GLASS 375MA 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
375 mA
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
0.171
CE, cURus
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208.500MXP
FUSE GLASS 500MA 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
500 mA
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
0.365
CE, cURus
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208006.MXP
FUSE GLASS 6A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
6 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
22.1
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208.750MXP
FUSE GLASS 750MA 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
750 mA
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
1.05
CE, cURus
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208008.MXP
FUSE GLASS 8A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
8 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
56
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208002.MXP
FUSE GLASS 2A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
2 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
1.5
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
020801.5MXP
FUSE GLASS 1.5A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
1.5 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
0.8
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
0208010.MXP
FUSE GLASS 10A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
10 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
116
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
020802.5MXP
FUSE GLASS 2.5A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
2.5 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
2.68
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)
020803.5MXP
FUSE GLASS 3.5A 350VAC 2AG
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Requires Holder
3.5 A
-55°C ~ 125°C
Fast Blow
208
Cartridge, Glass
350 V
2AG, 5mm x 15mm
100A
6.7
CE, cURus, PSE
0.185" Dia x 0.570" L (4.70mm x 14.48mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.