197 Series, Fuses

Results:
19
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Size / Dimension
Package / Case
Results remaining19
Applied Filters:
197
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorOperating TemperatureApproval AgencyMounting TypeVoltage Rating - ACCurrent Rating (Amps)SeriesFuse TypeResponse TimePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionVoltage Rating - DC
1971700000
FUSE GLASS 7A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Holder
125 V
7 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
140
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970300000
FUSE GLASS 300MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
300 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.038
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970500000
FUSE GLASS 500MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
500 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.19
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970250000
FUSE GLASS 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
250 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.019
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970600000
FUSE GLASS 600MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
600 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.31
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970350000
FUSE GLASS 350MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
350 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.065
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970400000
FUSE GLASS 400MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
400 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.092
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970700000
FUSE GLASS 700MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
700 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.43
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
1970800000
FUSE GLASS 800MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
250 V
800 mA
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
0.48
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19711000001
FUSE GLASS 1A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
1 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
35A
1.3
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19712500001
FUSE GLASS 2.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
2.5 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
10
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19713000001
FUSE GLASS 3A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
3 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
17
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19713500001
FUSE GLASS 3.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
3.5 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
26
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19714000001
FUSE GLASS 4A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
125 V
4 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
32
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19715000001
FUSE GLASS 5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
125 V
5 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
55
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19716000001
FUSE GLASS 6A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, UL
Requires Holder
125 V
6 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
10kA
96
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19711250001
FUSE GLASS 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
1.25 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
2.2
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19711600001
FUSE GLASS 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
1.6 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
4.3
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-
19712000001
FUSE GLASS 2A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-25°C ~ 70°C
cUL, METI, UL
Requires Holder
250 V
2 A
197
Cartridge, Glass
Medium Blow
5mm x 20mm
100A
8.6
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
-

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.