197 Series, Fuses

Results:
19
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Mounting Type
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Response Time
Color
Fuse Type
Size / Dimension
Package / Case
Results remaining19
Applied Filters:
197
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureVoltage Rating - ACSeriesFuse TypeCurrent Rating (Amps)Response TimePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / DimensionMounting Type
19711250001
FUSE GLASS 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
1.25 A
Medium Blow
5mm x 20mm
100A
2.2
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1971700000
FUSE GLASS 7A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
125 V
197
Cartridge, Glass
7 A
Medium Blow
5mm x 20mm
10kA
140
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Holder
19716000001
FUSE GLASS 6A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
125 V
197
Cartridge, Glass
6 A
Medium Blow
5mm x 20mm
10kA
96
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19715000001
FUSE GLASS 5A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
125 V
197
Cartridge, Glass
5 A
Medium Blow
5mm x 20mm
10kA
55
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19714000001
FUSE GLASS 4A 125VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
125 V
197
Cartridge, Glass
4 A
Medium Blow
5mm x 20mm
10kA
32
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19713500001
FUSE GLASS 3.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
3.5 A
Medium Blow
5mm x 20mm
100A
26
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19713000001
FUSE GLASS 3A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
3 A
Medium Blow
5mm x 20mm
100A
17
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19712500001
FUSE GLASS 2.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
2.5 A
Medium Blow
5mm x 20mm
100A
10
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19712000001
FUSE GLASS 2A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
2 A
Medium Blow
5mm x 20mm
100A
8.6
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19711600001
FUSE GLASS 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
1.6 A
Medium Blow
5mm x 20mm
100A
4.3
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970300000
FUSE GLASS 300MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
300 mA
Medium Blow
5mm x 20mm
35A
0.038
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19711000001
FUSE GLASS 1A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
1 A
Medium Blow
5mm x 20mm
35A
1.3
cUL, METI, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970800000
FUSE GLASS 800MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
800 mA
Medium Blow
5mm x 20mm
35A
0.48
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970700000
FUSE GLASS 700MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
700 mA
Medium Blow
5mm x 20mm
35A
0.43
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970400000
FUSE GLASS 400MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
400 mA
Medium Blow
5mm x 20mm
35A
0.092
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970350000
FUSE GLASS 350MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
350 mA
Medium Blow
5mm x 20mm
35A
0.065
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970600000
FUSE GLASS 600MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
600 mA
Medium Blow
5mm x 20mm
35A
0.31
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970250000
FUSE GLASS 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
250 mA
Medium Blow
5mm x 20mm
35A
0.019
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
1970500000
FUSE GLASS 500MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-25°C ~ 70°C
250 V
197
Cartridge, Glass
500 mA
Medium Blow
5mm x 20mm
35A
0.19
cUL, UL
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder

Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.