193 Series, Fuses

Results:
22
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Breaking Capacity @ Rated Voltage
Approval Agency
Operating Temperature
Response Time
Color
Fuse Type
Mounting Type
Size / Dimension
Voltage Rating - DC
Package / Case
Voltage Rating - AC
Results remaining22
Applied Filters:
193
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorVoltage Rating - DCOperating TemperatureApproval AgencyResponse TimeVoltage Rating - ACCurrent Rating (Amps)SeriesFuse TypePackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionMounting Type
19300501009
FUSE GLASS 50MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cULus
Fast Blow
250 V
50 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.005
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19300631009
FUSE GLASS 63MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cULus
Fast Blow
250 V
63 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.0079
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19300800001
FUSE GLASS 80MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
80 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.0032
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19301000001
FUSE GLASS 100MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
100 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.007
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19301250001
FUSE GLASS 125MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
125 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.014
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19301600001
FUSE GLASS 160MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
160 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.024
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19302000001
FUSE GLASS 200MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
200 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.018
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19302500001
FUSE GLASS 250MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
250 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.032
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19303150001
FUSE GLASS 315MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
315 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.062
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19304000001
FUSE GLASS 400MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
400 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.13
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19305000001
FUSE GLASS 500MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
500 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.23
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19306300001
FUSE GLASS 630MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
630 mA
193
Cartridge, Glass
5mm x 20mm
35A
0.44
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19308000001
FUSE GLASS 800MA 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
800 mA
193
Cartridge, Glass
5mm x 20mm
35A
1
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19311000001
FUSE GLASS 1A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
1 A
193
Cartridge, Glass
5mm x 20mm
35A
1.4
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19311250001
FUSE GLASS 1.25A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
1.25 A
193
Cartridge, Glass
5mm x 20mm
35A
2.7
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19311600001
FUSE GLASS 1.6A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
1.6 A
193
Cartridge, Glass
5mm x 20mm
35A
4.3
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19312000001
FUSE GLASS 2A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
2 A
193
Cartridge, Glass
5mm x 20mm
35A
7.8
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19312500001
FUSE GLASS 2.5A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
2.5 A
193
Cartridge, Glass
5mm x 20mm
35A
13
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19313150001
FUSE GLASS 3.15A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
3.15 A
193
Cartridge, Glass
5mm x 20mm
35A
20
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder
19314000001
FUSE GLASS 4A 250VAC 5X20MM
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
cURus, SEMKO, VDE
Fast Blow
250 V
4 A
193
Cartridge, Glass
5mm x 20mm
40A
21
0.205" Dia x 0.787" L (5.20mm x 20.00mm)
Requires Holder

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.