172876 Series, Fuses

Results:
62
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Voltage Rating - AC
Voltage Rating - DC
Operating Temperature
Response Time
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Package / Case
Color
Results remaining62
Applied Filters:
172876
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorOperating TemperatureResponse TimeCurrent Rating (Amps)Approval AgencySeriesFuse TypeVoltage Rating - ACVoltage Rating - DCPackage / CaseBreaking Capacity @ Rated VoltageMelting I²tSize / DimensionMounting Type
7010.9896.63
FUSE CERAMIC 15A 65VAC/VDC
Contact us
Quantity
1 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
15 A
cURus
172876
Cartridge, Ceramic
65 V
65 V
Cartridge, Non-Standard
300A
92
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9790.57
FUSE CERAMIC 500MA 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
500 mA
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.046
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9830.63
FUSE CERAMIC 2A 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
2 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.72
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9800.57
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
750 mA
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.09
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7195.9870.57
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
-
4 A
-
172876
Cartridge, Ceramic
-
-
Cartridge, Non-Standard
-
-
-
Surface Mount
7010.9760.53
172876 0.125 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
125 mA
-
172876
-
-
-
-
-
-
-
Surface Mount
7010.9750.53
172876 0.063 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
63 mOhms
-
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
-
0.00022
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7010.9890.57
FUSE CERAMIC 7A 63VAC 125VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
7 A
cURus
172876
Cartridge, Ceramic
63 V
125 V
Cartridge, Non-Standard
300A
8.5
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9830.57
FUSE CERAMIC 2A 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
2 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.72
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9800.63A
172876 FUSIBLE 750MA F A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
750 mA
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.09
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7010.9750.57
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
63 mA
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.00022
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7010.9800.53
172876 0.750 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
750 mA
-
172876
-
-
-
-
-
-
-
Surface Mount
7010.9860.63
FUSE CERAMIC 3.5A 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
3.5 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
1.7
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9840.63
FUSE CERAMIC 2.5A 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
2.5 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.91
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Requires Holder
7010.9780.57
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
375 mA
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.012
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7010.9892.53
172876 10 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
10 A
-
172876
Cartridge, Ceramic
-
-
Cartridge, Non-Standard
-
-
-
Surface Mount
7010.9870.53
172876 4 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
4 A
-
172876
Cartridge, Ceramic
-
-
Cartridge, Non-Standard
-
-
-
Surface Mount
7010.9820.57
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
1.5 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.25
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount
7010.9894.53
172876 12 BANDE 100
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-
Fast Blow
12 A
-
172876
Cartridge, Ceramic
-
-
Cartridge, Non-Standard
-
-
-
Surface Mount
7010.9840.57
FUSE CERAMIC 2.5A 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
-55°C ~ 125°C
Fast Blow
2.5 A
cURus
172876
Cartridge, Ceramic
125 V
125 V
Cartridge, Non-Standard
300A
0.91
0.079" Dia x 0.276" L (2.00mm x 7.00mm)
Surface Mount

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.