172322 Series, Fuses

Results:
91
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Approval Agency
Breaking Capacity @ Rated Voltage
Voltage Rating - DC
Voltage Rating - AC
Operating Temperature
Fuse Type
Size / Dimension
Package / Case
Response Time
Color
Mounting Type
Results remaining91
Applied Filters:
172322
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeResponse TimeVoltage Rating - DCOperating TemperatureCurrent Rating (Amps)SeriesFuse TypeVoltage Rating - ACPackage / CaseBreaking Capacity @ Rated VoltageMelting I²tApproval AgencySize / Dimension
7010.7160.49
172322 12 X 5000 LG85
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
32 V
-55°C ~ 85°C
12 A
172322
Board Mount (Cartridge Style Excluded)
32 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
57
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7010.39
172322 0.063 X 5000 LG65
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
63 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
0.0008
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7060.37
172322 0.750 X 1500 LG65
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
750 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.18
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7070.37
FUSE BRD MNT 1A 125VAC/VDC AXIAL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
1 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.3
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7060.39
172322 0.750 X 5000 LG65
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
750 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.18
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7010.47
FUSE BRD MT 63MA 125VAC/VDC CART
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
63 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.0008
CE, CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7010.13
FUSE BRD MT 63MA 125VAC/VDC CART
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
63 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.0008
CE, CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7140.13
FUSE BRD MNT 7A 125VAC/VDC AXIAL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
7 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
13
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7040.13
FUSE BOARD MNT 375MA 125VAC/VDC
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
375 mA
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
0.019
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7120.37
172322 4 X 1500 LG65
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
4 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
4
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7160.47
FUSE MSA COLOR CODED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
32 V
-55°C ~ 85°C
12 A
172322
Board Mount (Cartridge Style Excluded)
32 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
57
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7150.47
FUSE MSA COLOR CODED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
10 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
39
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7100.37
FUSE SCHURTER 2.5A
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
-
172322
Board Mount (Cartridge Style Excluded)
-
Cartridge, Non-Standard (Axial)
-
-
-
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7160.37
TYPE 172322 QUICK ACTING
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
32 V
-55°C ~ 85°C
12 A
172322
Board Mount (Cartridge Style Excluded)
32 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
57
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7170.47
FUSE MSA COLOR CODED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
32 V
-55°C ~ 85°C
15 A
172322
Board Mount (Cartridge Style Excluded)
32 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
90
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7100.49
FUSE TYPE 172322 2.5/125V
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
2.5 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
1.4
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7100.47
FUSE MSA COLOR CODED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
-
-55°C ~ 85°C
2.5 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
1.4
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7090.37
FUSE BRD MNT 2A 125VAC/VDC AXIAL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
2 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
1.1
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7140.47
FUSE MSA COLOR CODED
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
7 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
50A AC, 300A DC
13
CSA, GAM T1, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)
7010.7120.13
FUSE BRD MNT 4A 125VAC/VDC AXIAL
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Through Hole
Fast Blow
125 V
-55°C ~ 85°C
4 A
172322
Board Mount (Cartridge Style Excluded)
125 V
Cartridge, Non-Standard (Axial)
300A
4
CSA, UR
0.093" Dia x 0.315" L (2.36mm x 8.00mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.