1245HC Series, Fuses

Results:
3
Manufacturer
Series
Melting I²t
Current Rating (Amps)
Voltage Rating - DC
Operating Temperature
Response Time
Color
Approval Agency
Fuse Type
Breaking Capacity @ Rated Voltage
Mounting Type
Size / Dimension
Package / Case
Voltage Rating - AC
Results remaining3
Applied Filters:
1245HC
Select
ImageProduct DetailPriceAvailabilityECAD ModelColorMounting TypeOperating TemperatureResponse TimeVoltage Rating - ACCurrent Rating (Amps)Package / CaseApproval AgencySeriesFuse TypeVoltage Rating - DCBreaking Capacity @ Rated VoltageMelting I²tSize / Dimension
1245HC100-RTR
FUSE BRD 100A 125VAC 72VDC 2SMD
1+
$7.4054
5+
$6.9939
10+
$6.5825
Quantity
20,000 Available
Can ship immediately
Ships from: HK
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
Fast Blow
125 V
100 A
2-SMD, Square End Block
cURus, UL
1245HC
Board Mount (Cartridge Style Excluded)
72 V
500A AC, 1kA DC
5000
0.484" L x 0.177" W x 0.177" H (12.30mm x 4.50mm x 4.50mm)
1245HC60-RTR
FUSE BRD 60A 125VAC 80VDC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
Fast Blow
125 V
60 A
2-SMD, Square End Block
cURus, UL
1245HC
Board Mount (Cartridge Style Excluded)
80 V
500A AC, 1kA DC
950
0.484" L x 0.177" W x 0.177" H (12.30mm x 4.50mm x 4.50mm)
1245HC80-RTR
FUSE BRD 80A 125VAC 72VDC 2SMD
Contact us
Quantity
Contact us
PCB Symbol, Footprint & 3D Model
-
Surface Mount
-55°C ~ 125°C
Fast Blow
125 V
80 A
2-SMD, Square End Block
cURus, UL
1245HC
Board Mount (Cartridge Style Excluded)
72 V
500A AC, 1kA DC
1700
0.484" L x 0.177" W x 0.177" H (12.30mm x 4.50mm x 4.50mm)

About  Fuses

Fuses are specialized devices designed to interrupt the flow of electrical current in a circuit when the current exceeds a specific threshold, providing protection against overcurrent conditions. They consist of a conductor that is intentionally designed to melt and open the circuit when exposed to excessive current, thereby preventing damage to the connected components or equipment. When the current flowing through a fuse surpasses its rated capacity, the heat generated within the fuse causes the conducting element to melt or blow, creating an open circuit and stopping the flow of electricity. This action effectively protects the circuit and connected devices from potential damage caused by excessive current flow. Fuses are available in various types and configurations, including fast-acting and slow-blow fuses, each with different response times to overcurrent conditions. Fast-acting fuses respond quickly to overloads, while slow-blow fuses offer a delayed response and can withstand temporary current surges without blowing. The selection of the appropriate fuse type depends on the specific requirements of the electrical circuit being protected. By using fuses with the correct characteristics, the risk of damage to equipment and hazards resulting from excessive current flow can be minimized, ensuring the safe and reliable operation of electrical systems.